<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">378843400</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123305.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20031201xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1524/teme.70.12.557.20266</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.1524/teme.70.12.557.20266</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Jägle</subfield>
   <subfield code="D">Martin</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Hochempfindliches, schnelles Nanokalorimeter (A Fast and Highly Sensitive Nano-Calorimeter)</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Martin Jägle]</subfield>
  </datafield>
  <datafield tag="246" ind1="0" ind2=" ">
   <subfield code="a">A Fast and Highly Sensitive Nano-Calorimeter</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Die vorliegende Publikation fasst die Ergebnisse des bmb+f-Pilotprojekts NanoCal zusammen. Ziel war die Erforschung, der Aufbau und der Test eines hochempfindlichen, schnellen Differential-Multiparameter-Nanokalorimeters beispielsweise für Untersuchungen der Faltungsdynamik von Proteinen und von Relaxationszeiten in Lipidmembranen. Dabei wurden die Grundlagen für die Entwicklung eines mikrostrukturierten Kalorimeterchips gelegt, welcher ähnlich empfindlich wie moderne Kalorimeter ist, durch die Miniaturisierung jedoch nicht nur deutlich kleinere Analytmengen zur Vermessung benötigt, sondern auch eine geringere Ansprechzeit aufweisen soll. Es wurden erste Demonstratorkalorimeter auf 4&quot;-Wafer-Basis hergestellt. Die durch das thermische Rauschen begrenzte Temperaturauflösung lag bei ca. 75 μK. Dies entspricht einer Leistungsauflösung von ungefähr 2 μW. Aus den gewonnenen Daten lässt sich, da der technologische Weg nun vorgezeichnet ist, über ein Redesign der Kalorimeterlayouts die Leistungsfähigkeit der Kalorimeterchips weiter verbessern.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">© 2003 Oldenbourg Wissenschaftsverlag GmbH</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Engineering: general</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Instruments &amp; instrumentation engineering</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Materials science</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">tm - Technisches Messen/Sensoren, Geräte, Systeme</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">70/12/2003(2003-12-01), 557-560</subfield>
   <subfield code="x">0171-8096</subfield>
   <subfield code="q">70:12/2003&lt;557</subfield>
   <subfield code="1">2003</subfield>
   <subfield code="2">70</subfield>
   <subfield code="o">teme</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1524/teme.70.12.557.20266</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1524/teme.70.12.557.20266</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Jägle</subfield>
   <subfield code="D">Martin</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">tm - Technisches Messen/Sensoren, Geräte, Systeme</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">70/12/2003(2003-12-01), 557-560</subfield>
   <subfield code="x">0171-8096</subfield>
   <subfield code="q">70:12/2003&lt;557</subfield>
   <subfield code="1">2003</subfield>
   <subfield code="2">70</subfield>
   <subfield code="o">teme</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
