Ein neuartiges passives Paradigma der funktionellen Magnetresonanztomographie (fMRT) zur Hirnfunktionsanalyse (A Novel Passive Paradigm for Functional Magnetic Resonance Imaging (fMRI) to Localize Brain Functions)
Gespeichert in:
Verfasser / Beitragende:
[Thomas Gasser, Ibrahim Erol Sandalcioglu, Volker Skwarek, Elke Gizewski, Dietmar Stolke, Volker Hans]
Ort, Verlag, Jahr:
2003
Enthalten in:
tm - Technisches Messen/Sensoren, Geräte, Systeme, 70/9/2003(2003-09-01), 449-456
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 378852140 | ||
| 003 | CHVBK | ||
| 005 | 20180305123326.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 161128e20030901xx s 000 0 ger | ||
| 024 | 7 | 0 | |a 10.1524/teme.70.9.449.20251 |2 doi |
| 035 | |a (NATIONALLICENCE)gruyter-10.1524/teme.70.9.449.20251 | ||
| 245 | 0 | 4 | |a Ein neuartiges passives Paradigma der funktionellen Magnetresonanztomographie (fMRT) zur Hirnfunktionsanalyse (A Novel Passive Paradigm for Functional Magnetic Resonance Imaging (fMRI) to Localize Brain Functions) |h [Elektronische Daten] |c [Thomas Gasser, Ibrahim Erol Sandalcioglu, Volker Skwarek, Elke Gizewski, Dietmar Stolke, Volker Hans] |
| 246 | 1 | |a A Novel Passive Paradigm for Functional Magnetic Resonance Imaging (fMRI) to Localize Brain Functions | |
| 520 | 3 | |a Die Entwicklung einer elektromagnetisch abgeschirmten Vorrichtung zur Nutzung einer elektrischen Nervenstimulation als passives fMRT-Paradigma ist Inhalt der Arbeit. Im Besonderen wird auf die technische Bedeutung der Abschirmung und die Wahl der Stimulationsparameter eingegangen. Die klinische Bedeutung für den neurochirurgischen Patienten wird anhand der Ergebnisse klinischer Studien dargestellt. Dem Neurochirurgen werden mit diesem Verfahren Informationen über die funktionelle Anatomie des Patienten zur Verfügung gestellt, um eine Schonung funktionell relevanter Hirnstrukturen zu erleichtern. | |
| 540 | |a © 2003 Oldenbourg Wissenschaftsverlag GmbH | ||
| 690 | 7 | |a Engineering: general |2 nationallicence | |
| 690 | 7 | |a Instruments & instrumentation engineering |2 nationallicence | |
| 690 | 7 | |a Materials science |2 nationallicence | |
| 700 | 1 | |a Gasser |D Thomas |4 aut | |
| 700 | 1 | |a Sandalcioglu |D Ibrahim Erol |4 aut | |
| 700 | 1 | |a Skwarek |D Volker |4 aut | |
| 700 | 1 | |a Gizewski |D Elke |4 aut | |
| 700 | 1 | |a Stolke |D Dietmar |4 aut | |
| 700 | 1 | |a Hans |D Volker |4 aut | |
| 773 | 0 | |t tm - Technisches Messen/Sensoren, Geräte, Systeme |d Oldenbourg Wissenschaftsverlag GmbH |g 70/9/2003(2003-09-01), 449-456 |x 0171-8096 |q 70:9/2003<449 |1 2003 |2 70 |o teme | |
| 856 | 4 | 0 | |u https://doi.org/10.1524/teme.70.9.449.20251 |q text/html |z Onlinezugriff via DOI |
| 908 | |D 1 |a research article |2 jats | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1524/teme.70.9.449.20251 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Gasser |D Thomas |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Sandalcioglu |D Ibrahim Erol |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Skwarek |D Volker |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Gizewski |D Elke |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Stolke |D Dietmar |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Hans |D Volker |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t tm - Technisches Messen/Sensoren, Geräte, Systeme |d Oldenbourg Wissenschaftsverlag GmbH |g 70/9/2003(2003-09-01), 449-456 |x 0171-8096 |q 70:9/2003<449 |1 2003 |2 70 |o teme | ||
| 900 | 7 | |b CC0 |u http://creativecommons.org/publicdomain/zero/1.0 |2 nationallicence | |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-gruyter | ||