Profiling and in vivo Quantification of Proteins by High Resolution Mass Spectrometry: The Example of Goserelin, an Analogue of Luteinizing Hormone-Releasing Hormone

Verfasser / Beitragende:
[Sophie Michalet, Philippe Favreau, Reto Stöcklin]
Ort, Verlag, Jahr:
2003
Enthalten in:
Clinical Chemistry and Laboratory Medicine, 41/12(2003-12-04), 1589-1598
Format:
Artikel (online)
ID: 378853473
LEADER caa a22 4500
001 378853473
003 CHVBK
005 20180305123329.0
007 cr unu---uuuuu
008 161128e20031204xx s 000 0 eng
024 7 0 |a 10.1515/CCLM.2003.242  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1515/CCLM.2003.242 
245 0 0 |a Profiling and in vivo Quantification of Proteins by High Resolution Mass Spectrometry: The Example of Goserelin, an Analogue of Luteinizing Hormone-Releasing Hormone  |h [Elektronische Daten]  |c [Sophie Michalet, Philippe Favreau, Reto Stöcklin] 
520 3 |a Proteins are essential biomolecules which are frequently involved in major pathological syndromes and are widely used as diagnostic markers or therapeutic agents. The emergence of proteomics will doubtless further increase the significance of proteins both in the clinic and in the life sciences in general. Our main objective is to offer innovative solutions to what we like to call the "post-proteomics era”. To achieve our goal, we intend to develop novel approaches and technologies for in vivo metabolic studies of proteins using mass spectrometry (MS), focusing on pharmacokinetics and pharmacodynamics. Using goserelin as a model, we have successfully developed and validated a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection and quantification of an intact analogue of luteinizing hormone-releasing hormone (LHRH) in small volumes of rat plasma samples at concentrations ranging from 0.3 to 405.0 μg/l. To this end, a microbore reversed-phase-HPLC system was coupled on-line to a tandem high resolution quadrupole time-of-flight (Q-TOF) instrument fitted with an electrospray ion source and operated in LC-MS/MS mode. External calibration was used and the high resolution was crucial to discard contaminating signals, which would not have been possible with the more conventional triple quadrupole mass spectrometers operated in a static mode. For low sample amounts, calibration curves were constructed corresponding to rat plasma levels of 0.3 to 16.4 μg/l and found to be of third order with a coefficient of determination greater than 0.999. The relative standard deviation was found to be lower than 15%. A lower limit of detection (LLOD) of 0.17 μg/l and a lower limit of quantification (LLOQ) of 0.3 μg/l were determined. 
540 |a Copyright © 2003 by Walter de Gruyter GmbH & Co. KG 
690 7 |a Medical equipment & techniques  |2 nationallicence 
690 7 |a Medical diagnosis  |2 nationallicence 
690 7 |a Diseases & disorders  |2 nationallicence 
700 1 |a Michalet  |D Sophie  |4 aut 
700 1 |a Favreau  |D Philippe  |4 aut 
700 1 |a Stöcklin  |D Reto  |4 aut 
773 0 |t Clinical Chemistry and Laboratory Medicine  |d Walter de Gruyter  |g 41/12(2003-12-04), 1589-1598  |x 1434-6621  |q 41:12<1589  |1 2003  |2 41  |o cclm 
856 4 0 |u https://doi.org/10.1515/CCLM.2003.242  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1515/CCLM.2003.242  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Michalet  |D Sophie  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Favreau  |D Philippe  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Stöcklin  |D Reto  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Clinical Chemistry and Laboratory Medicine  |d Walter de Gruyter  |g 41/12(2003-12-04), 1589-1598  |x 1434-6621  |q 41:12<1589  |1 2003  |2 41  |o cclm 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter