<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">378867180</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123400.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20030617xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1515/CCLM.2003.116</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.1515/CCLM.2003.116</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Bossuyt</subfield>
   <subfield code="D">Xavier</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Separation of Serum Proteins by Automated Capillary Zone Electrophoresis</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Xavier Bossuyt]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Capillary zone electrophoresis (CZE) of serum proteins is increasingly gaining impact in clinical laboratories. Two automated multichannel instruments dedicated to the separation of serum proteins have become available over the last 6 years, the Paragon CZE 2000® (Beckman Coulter, CA, USA) and, more recently, the Capillarys® (Sebia, France). This review focuses on the performance of these commercial instruments to separate serum proteins in a clinical laboratory setting. The utility of CZE to recognize various dysproteinemias and to detect and identify monoclonal proteins will be described and systematically reviewed. The reader will be provided with a summation and an understanding of CZE-specific interference.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Copyright © 2003 by Walter de Gruyter GmbH &amp; Co. KG</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Medical equipment &amp; techniques</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Medical diagnosis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Diseases &amp; disorders</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Clinical Chemistry and Laboratory Medicine</subfield>
   <subfield code="d">Walter de Gruyter</subfield>
   <subfield code="g">41/6(2003-06-17), 762-772</subfield>
   <subfield code="x">1434-6621</subfield>
   <subfield code="q">41:6&lt;762</subfield>
   <subfield code="1">2003</subfield>
   <subfield code="2">41</subfield>
   <subfield code="o">cclm</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1515/CCLM.2003.116</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1515/CCLM.2003.116</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Bossuyt</subfield>
   <subfield code="D">Xavier</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Clinical Chemistry and Laboratory Medicine</subfield>
   <subfield code="d">Walter de Gruyter</subfield>
   <subfield code="g">41/6(2003-06-17), 762-772</subfield>
   <subfield code="x">1434-6621</subfield>
   <subfield code="q">41:6&lt;762</subfield>
   <subfield code="1">2003</subfield>
   <subfield code="2">41</subfield>
   <subfield code="o">cclm</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
