Capillary Zone Electrophoresis of Serum Proteins: Effects of Changed Analytical Conditions
Gespeichert in:
Verfasser / Beitragende:
[Paola Luraschi, Elisabetta Dalla Dea, Carlo Franzini]
Ort, Verlag, Jahr:
2003
Enthalten in:
Clinical Chemistry and Laboratory Medicine, 41/6(2003-06-17), 782-786
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 378867253 | ||
| 003 | CHVBK | ||
| 005 | 20180305123400.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 161128e20030617xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1515/CCLM.2003.118 |2 doi |
| 035 | |a (NATIONALLICENCE)gruyter-10.1515/CCLM.2003.118 | ||
| 245 | 0 | 0 | |a Capillary Zone Electrophoresis of Serum Proteins: Effects of Changed Analytical Conditions |h [Elektronische Daten] |c [Paola Luraschi, Elisabetta Dalla Dea, Carlo Franzini] |
| 520 | 3 | |a Analytical conditions in a system for capillary zone electrophoresis (Beckman Paragon CZE 2000) were originally selected to allow serum protein separation into five discrete protein zones, corresponding to those of conventional clinical electrophoresis. To improve the system's performance, new analytical conditions have been made available. We compared the two sets of conditions ("new" = y; "old" = x) for possible variations of results caused by the change. One hundred thirteen serum samples, covering wide intervals of values, were assayed on two twin instruments working under the old and the new conditions; results were assessed statistically and graphically. Possible clinical significance of differences was checked by comparison with the biological variation-based quality specifications for bias. Statistically significant (y-x) differences were observed for the α1-, α2- and β-globulin zones; clinically significant differences were observed for all the zones, with the exception of the γ-globulin zone. Therefore, old/new regression equations were calculated, whose reliability was assured by the wide interval of values, by the large sample size, and by the low dispersion of single values around the mean concordance estimates. Such equations may be used to convert "old" into "new" reference values, and for the intercomparison of patient results obtained under different analytical conditions. | |
| 540 | |a Copyright © 2003 by Walter de Gruyter GmbH & Co. KG | ||
| 690 | 7 | |a Medical equipment & techniques |2 nationallicence | |
| 690 | 7 | |a Medical diagnosis |2 nationallicence | |
| 690 | 7 | |a Diseases & disorders |2 nationallicence | |
| 700 | 1 | |a Luraschi |D Paola |4 aut | |
| 700 | 1 | |a Dea |D Elisabetta Dalla |4 aut | |
| 700 | 1 | |a Franzini |D Carlo |4 aut | |
| 773 | 0 | |t Clinical Chemistry and Laboratory Medicine |d Walter de Gruyter |g 41/6(2003-06-17), 782-786 |x 1434-6621 |q 41:6<782 |1 2003 |2 41 |o cclm | |
| 856 | 4 | 0 | |u https://doi.org/10.1515/CCLM.2003.118 |q text/html |z Onlinezugriff via DOI |
| 908 | |D 1 |a research article |2 jats | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1515/CCLM.2003.118 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Luraschi |D Paola |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Dea |D Elisabetta Dalla |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Franzini |D Carlo |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Clinical Chemistry and Laboratory Medicine |d Walter de Gruyter |g 41/6(2003-06-17), 782-786 |x 1434-6621 |q 41:6<782 |1 2003 |2 41 |o cclm | ||
| 900 | 7 | |b CC0 |u http://creativecommons.org/publicdomain/zero/1.0 |2 nationallicence | |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-gruyter | ||