<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">378875310</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123419.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20030401xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1524/teme.70.4.173.20186</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.1524/teme.70.4.173.20186</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Hochauflösende Ultraschall-Entfernungsmessung für große Distanzen (High Resolution Ultrasonic Distance Measurement for Long Distances)</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Hannes Elmer, Herbert Schweinzer, Gottfried Magerl]</subfield>
  </datafield>
  <datafield tag="246" ind1="1" ind2=" ">
   <subfield code="a">High Resolution Ultrasonic Distance Measurement for Long Distances</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Dieser Beitrag gibt einen Überblick über Probleme ultraschallbasierter Entfernungsmesssysteme für industrielle Anwendungen. Das 1-Bit-Korrelationsverfahren vereinfacht die Behandlung der stark unterschiedlichen Empfangspegel und die Echtzeitsignalverarbeitung. Der Vergleich der A-B-Messung mit auf passiver Reflexion basierenden Verfahren führt zu der neuen Methode der aktiven Reflexion. Weiterhin wird ein Ultraschall-Wandler analysiert und sein Einfluss auf breitbandige Signale bei Verwendung korrelativer Empfänger diskutiert.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">© 2003 Oldenbourg Wissenschaftsverlag GmbH</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Engineering: general</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Instruments &amp; instrumentation engineering</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Materials science</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Elmer</subfield>
   <subfield code="D">Hannes</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Schweinzer</subfield>
   <subfield code="D">Herbert</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Magerl</subfield>
   <subfield code="D">Gottfried</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">tm - Technisches Messen/Sensoren, Geräte, Systeme</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">70/4/2003(2003-04-01), 173-179</subfield>
   <subfield code="x">0171-8096</subfield>
   <subfield code="q">70:4/2003&lt;173</subfield>
   <subfield code="1">2003</subfield>
   <subfield code="2">70</subfield>
   <subfield code="o">teme</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1524/teme.70.4.173.20186</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1524/teme.70.4.173.20186</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Elmer</subfield>
   <subfield code="D">Hannes</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Schweinzer</subfield>
   <subfield code="D">Herbert</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Magerl</subfield>
   <subfield code="D">Gottfried</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">tm - Technisches Messen/Sensoren, Geräte, Systeme</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">70/4/2003(2003-04-01), 173-179</subfield>
   <subfield code="x">0171-8096</subfield>
   <subfield code="q">70:4/2003&lt;173</subfield>
   <subfield code="1">2003</subfield>
   <subfield code="2">70</subfield>
   <subfield code="o">teme</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
