Requirements for Reproducibility, Truenessand Error of Measurement in Internal QualityControl Schemes
Gespeichert in:
Verfasser / Beitragende:
[Piero Bonvicini, Paolo Metus, Maria A. Pavón, Massimo Tocchini]
Ort, Verlag, Jahr:
2003
Enthalten in:
Clinical Chemistry and Laboratory Medicine, 41/5(2003-05-15), 693-699
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 378876023 | ||
| 003 | CHVBK | ||
| 005 | 20180305123420.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 161128e20030515xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1515/CCLM.2003.105 |2 doi |
| 035 | |a (NATIONALLICENCE)gruyter-10.1515/CCLM.2003.105 | ||
| 245 | 0 | 0 | |a Requirements for Reproducibility, Truenessand Error of Measurement in Internal QualityControl Schemes |h [Elektronische Daten] |c [Piero Bonvicini, Paolo Metus, Maria A. Pavón, Massimo Tocchini] |
| 520 | 3 | |a Among the various models proposed to meet requirements for metrological performance in clinical laboratory measurements, that most widely used is intraand inter-biological variation. However, this model has weaknesses: a) in some cases, intra-individual biological variation is so small that requirements based on such data may not be met by routine methods; b) there is great variation among the intra- and inter-individual biological variations themselves. We therefore propose integration between "state-of-the-art” methods to minimize imprecision, and also suggest that requirements calculated on the basis of biological variations should be used in setting requirements for minimizing imprecision. Furthermore, we describe a new scale for setting requirements from biological variation data and suggest that systematic error should be corrected whenever it is statistically significant. | |
| 540 | |a Copyright © 2003 by Walter de Gruyter GmbH & Co. KG | ||
| 690 | 7 | |a Medical equipment & techniques |2 nationallicence | |
| 690 | 7 | |a Medical diagnosis |2 nationallicence | |
| 690 | 7 | |a Diseases & disorders |2 nationallicence | |
| 700 | 1 | |a Bonvicini |D Piero |4 aut | |
| 700 | 1 | |a Metus |D Paolo |4 aut | |
| 700 | 1 | |a Pavón |D Maria A. |4 aut | |
| 700 | 1 | |a Tocchini |D Massimo |4 aut | |
| 773 | 0 | |t Clinical Chemistry and Laboratory Medicine |d Walter de Gruyter |g 41/5(2003-05-15), 693-699 |x 1434-6621 |q 41:5<693 |1 2003 |2 41 |o cclm | |
| 856 | 4 | 0 | |u https://doi.org/10.1515/CCLM.2003.105 |q text/html |z Onlinezugriff via DOI |
| 908 | |D 1 |a research article |2 jats | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1515/CCLM.2003.105 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Bonvicini |D Piero |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Metus |D Paolo |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Pavón |D Maria A. |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Tocchini |D Massimo |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Clinical Chemistry and Laboratory Medicine |d Walter de Gruyter |g 41/5(2003-05-15), 693-699 |x 1434-6621 |q 41:5<693 |1 2003 |2 41 |o cclm | ||
| 900 | 7 | |b CC0 |u http://creativecommons.org/publicdomain/zero/1.0 |2 nationallicence | |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-gruyter | ||