Automated Serum Protein Electrophoresis byCapillarys®

Verfasser / Beitragende:
[Xavier Bossuyt, Bénédicte Lissoir, Godelieve Mariën, Diane Maisin, Jozef Vunckx, Norbert Blanckaert, Pierre Wallemacq]
Ort, Verlag, Jahr:
2003
Enthalten in:
Clinical Chemistry and Laboratory Medicine, 41/5(2003-05-15), 704-710
Format:
Artikel (online)
ID: 378876066
LEADER caa a22 4500
001 378876066
003 CHVBK
005 20180305123420.0
007 cr unu---uuuuu
008 161128e20030515xx s 000 0 eng
024 7 0 |a 10.1515/CCLM.2003.107  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1515/CCLM.2003.107 
245 0 0 |a Automated Serum Protein Electrophoresis byCapillarys®  |h [Elektronische Daten]  |c [Xavier Bossuyt, Bénédicte Lissoir, Godelieve Mariën, Diane Maisin, Jozef Vunckx, Norbert Blanckaert, Pierre Wallemacq] 
520 3 |a Capillary zone electrophoresis (CZE) of serum proteins is increasingly gaining impact in clinical laboratories. In this report, we evaluate automated capillary zone electrophoresis by Capillarys® (Sebia, France). Withinrun and between-run imprecision for the five electrophoretic fractions was <2% and <6%, respectively. Data obtained with Capillarys correlated with results obtained with agarose gel electrophoresis and Paragon CZE® 2000 (Beckman Coulter, USA). Analysis of serum obtained from patients with inflammation, nephrotic syndrome, bisalbuminemia, and α1-antitrypsin deficiency revealed that Capillarys was able to detect these abnormalities. Two hundred thirty eight samples were analyzed by agarose gel electrophoresis, Capillarys, capillary electrophoresis using Paragon CZE 2000 system, and immunofixation. Sample selection was based on the presence of a disturbed morphology (e.g., spike) of the protein profile or hypogammaglobulinemia on agarose gel electrophoresis and/or Capillarys. Immunofixation revealed the presence of a monoclonal protein, oligoclonal bands, polyclonal pattern, and a normal profile in, respectively, 89, 66, 19, and 64 samples. With Capillarys, Paragon, and agarose gel electrophoresis, a spike and/or disturbed morphology of the profile was found in 222, 182, and 180 samples, respectively. In these samples, immunofixation was negative in 73 (33%), 46 (25%), and 39 (22%) samples, respectively. These data indicate that Capillarys has a lower specificity than agarose gel electrophoresis and Paragon 2000. Of the 89 samples with a monoclonal protein, Capillarys, Paragon, and agarose gel electrophoresis failed to detect, respectively, three, three, and one monoclonal protein(s). Interferences by radio-opaque agents, complement degradation products, fibrinogen, and triglycerides are described. In conclusion, automated capillary zone electrophoresis with Capillarys provides for reproducible, rapid, and reliable serum electrophoresis. 
540 |a Copyright © 2003 by Walter de Gruyter GmbH & Co. KG 
690 7 |a Medical equipment & techniques  |2 nationallicence 
690 7 |a Medical diagnosis  |2 nationallicence 
690 7 |a Diseases & disorders  |2 nationallicence 
700 1 |a Bossuyt  |D Xavier  |4 aut 
700 1 |a Lissoir  |D Bénédicte  |4 aut 
700 1 |a Mariën  |D Godelieve  |4 aut 
700 1 |a Maisin  |D Diane  |4 aut 
700 1 |a Vunckx  |D Jozef  |4 aut 
700 1 |a Blanckaert  |D Norbert  |4 aut 
700 1 |a Wallemacq  |D Pierre  |4 aut 
773 0 |t Clinical Chemistry and Laboratory Medicine  |d Walter de Gruyter  |g 41/5(2003-05-15), 704-710  |x 1434-6621  |q 41:5<704  |1 2003  |2 41  |o cclm 
856 4 0 |u https://doi.org/10.1515/CCLM.2003.107  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1515/CCLM.2003.107  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Bossuyt  |D Xavier  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Lissoir  |D Bénédicte  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Mariën  |D Godelieve  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Maisin  |D Diane  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Vunckx  |D Jozef  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Blanckaert  |D Norbert  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Wallemacq  |D Pierre  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Clinical Chemistry and Laboratory Medicine  |d Walter de Gruyter  |g 41/5(2003-05-15), 704-710  |x 1434-6621  |q 41:5<704  |1 2003  |2 41  |o cclm 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter