Evaluation of ovotransferrin-matrix metal-affinity metalloprotein chromatography for Pu(IV) separations

Verfasser / Beitragende:
[W. K. Myers, C. E. Ruggiero, S. D. Reilly, M. P. Neu]
Ort, Verlag, Jahr:
2003
Enthalten in:
Radiochimica Acta/International journal for chemical aspects of nuclear science and technology, 91/12/2003(2003-12-01), 697-704
Format:
Artikel (online)
ID: 378878379
LEADER caa a22 4500
001 378878379
003 CHVBK
005 20180305123426.0
007 cr unu---uuuuu
008 161128e20031201xx s 000 0 eng
024 7 0 |a 10.1524/ract.91.12.697.23418  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1524/ract.91.12.697.23418 
245 0 0 |a Evaluation of ovotransferrin-matrix metal-affinity metalloprotein chromatography for Pu(IV) separations  |h [Elektronische Daten]  |c [W. K. Myers, C. E. Ruggiero, S. D. Reilly, M. P. Neu] 
520 3 |a Metal-Affinity metalloprotein chromatography has been suggested to have potential for selectively removing actinides from solution. To evaluate this potential, characterization of Pu(IV) and Fe(III) binding to an ovotransferrin-Sepharose™ 4B matrix, with oxalate and carbonate synergistic anions, was performed. Metal binding capacity was determined for metal concentrations ranging from 2×10-6 to 1×10-3M Fe(III) and 2.9×10-5 to 2.6×10-4M Pu(IV), where both metals were added as a solution of 10:1 nitrilotriacetic acid:metal. Metal binding capacity was also determined over the pH range 3.0 to 9.2. The metal binding properties of the immobilized ovotransferrin were found to differ from those reported for free-protein studies. Distribution coefficients were low: for metal solution concentrations of 0.02, 0.04, 0.10, and 0.20mM, coefficients were 540, 180, 23, and 12mL/g for Fe(III) and 20, 12, 7.2, and 6.0mL/g for Pu(IV), respectively. The capacity of the material was less dependent on pH than expected, varying by only two μmoles metal/g matrix for both Fe(III) and Pu(IV) over the pH range of 4.2 to 9.5. This study illustrates limitations of metalloprotein chromatography for Pu(IV) separation. 
540 |a © 2003 Oldenbourg Wissenschaftsverlag GmbH 
690 7 |a Laboratory techniques, experiments  |2 nationallicence 
690 7 |a Analytical chemistry  |2 nationallicence 
690 7 |a Inorganic chemistry  |2 nationallicence 
700 1 |a Myers  |D W. K.  |4 aut 
700 1 |a Ruggiero  |D C. E.  |4 aut 
700 1 |a Reilly  |D S. D.  |4 aut 
700 1 |a Neu  |D M. P.  |4 aut 
773 0 |t Radiochimica Acta/International journal for chemical aspects of nuclear science and technology  |d Oldenbourg Wissenschaftsverlag GmbH  |g 91/12/2003(2003-12-01), 697-704  |x 0033-8230  |q 91:12/2003<697  |1 2003  |2 91  |o ract 
856 4 0 |u https://doi.org/10.1524/ract.91.12.697.23418  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1524/ract.91.12.697.23418  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Myers  |D W. K.  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ruggiero  |D C. E.  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Reilly  |D S. D.  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Neu  |D M. P.  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Radiochimica Acta/International journal for chemical aspects of nuclear science and technology  |d Oldenbourg Wissenschaftsverlag GmbH  |g 91/12/2003(2003-12-01), 697-704  |x 0033-8230  |q 91:12/2003<697  |1 2003  |2 91  |o ract 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter