Validation of an Automated Immunoturbidimetric Assay for Measurement of Plasma D-Dimer
Gespeichert in:
Verfasser / Beitragende:
[Mojca Božič, Mojca Stegnar]
Ort, Verlag, Jahr:
2003
Enthalten in:
Clinical Chemistry and Laboratory Medicine, 41/7(2003-07-21), 958-962
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 378879332 | ||
| 003 | CHVBK | ||
| 005 | 20180305123428.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 161128e20030721xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1515/CCLM.2003.146 |2 doi |
| 035 | |a (NATIONALLICENCE)gruyter-10.1515/CCLM.2003.146 | ||
| 245 | 0 | 0 | |a Validation of an Automated Immunoturbidimetric Assay for Measurement of Plasma D-Dimer |h [Elektronische Daten] |c [Mojca Božič, Mojca Stegnar] |
| 520 | 3 | |a The performance characteristics and diagnostic accuracy of a new rapid automated quantitative immunoturbidimetric D-dimer assay, Auto-Dimer (Biopool, Umeå, Sweden) were evaluated in a population of 135 outpatients with suspected deep-vein thrombosis of lower limb. Enzyme-linked immunosorbent assay was used as the reference method. The Auto-Dimer assay showed good reproducibility. The correlation between Auto-Dimer and enzyme-linked immunosorbent assay was high (r = 0.91, p < 0.05) and agreement in classifying patients above or below the cut-off was good (κ coefficient 0.74, 95 % CI 0.62-0.86). At a cut-off of 340 μg/l the sensitivity and specificity of Auto-Dimer were high (100% and 61%, respectively). These data show that Auto-Dimer is a reliable screening test for exclusion of deep-vein thrombosis. The assay could be included in prospective patient management studies in order to obtain further information on its clinical usefulness. | |
| 540 | |a Copyright © 2003 by Walter de Gruyter GmbH & Co. KG | ||
| 690 | 7 | |a Medical equipment & techniques |2 nationallicence | |
| 690 | 7 | |a Medical diagnosis |2 nationallicence | |
| 690 | 7 | |a Diseases & disorders |2 nationallicence | |
| 700 | 1 | |a Božič |D Mojca |4 aut | |
| 700 | 1 | |a Stegnar |D Mojca |4 aut | |
| 773 | 0 | |t Clinical Chemistry and Laboratory Medicine |d Walter de Gruyter |g 41/7(2003-07-21), 958-962 |x 1434-6621 |q 41:7<958 |1 2003 |2 41 |o cclm | |
| 856 | 4 | 0 | |u https://doi.org/10.1515/CCLM.2003.146 |q text/html |z Onlinezugriff via DOI |
| 908 | |D 1 |a research article |2 jats | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1515/CCLM.2003.146 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Božič |D Mojca |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Stegnar |D Mojca |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Clinical Chemistry and Laboratory Medicine |d Walter de Gruyter |g 41/7(2003-07-21), 958-962 |x 1434-6621 |q 41:7<958 |1 2003 |2 41 |o cclm | ||
| 900 | 7 | |b CC0 |u http://creativecommons.org/publicdomain/zero/1.0 |2 nationallicence | |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-gruyter | ||