Comparability of Eight Immunoassay Procedures for the Determination of CA 15-3 and Related Markers

Verfasser / Beitragende:
[Petr Stern, Vladimir Bartos, Jaroslava Vavrova, Drahomira Bezdickova, Martina Pechova, Jana Uhrova, Bedrich Friedecky, Ludek Sprongl, Tomas Zima, Vladimir Palicka]
Ort, Verlag, Jahr:
2003
Enthalten in:
Clinical Chemistry and Laboratory Medicine, 41/8(2003-08-07), 1087-1094
Format:
Artikel (online)
ID: 378881574
LEADER caa a22 4500
001 378881574
003 CHVBK
005 20180305123433.0
007 cr unu---uuuuu
008 161128e20030807xx s 000 0 eng
024 7 0 |a 10.1515/CCLM.2003.168  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1515/CCLM.2003.168 
245 0 0 |a Comparability of Eight Immunoassay Procedures for the Determination of CA 15-3 and Related Markers  |h [Elektronische Daten]  |c [Petr Stern, Vladimir Bartos, Jaroslava Vavrova, Drahomira Bezdickova, Martina Pechova, Jana Uhrova, Bedrich Friedecky, Ludek Sprongl, Tomas Zima, Vladimir Palicka] 
520 3 |a MUC1 mucins are tumour markers that are frequently indicated and examined, particularly as part of the treatment of breast cancer. Relatively large differences were observed in external quality assessment (EQA) between the results that were obtained by different immunoassay technologies. Thus, we compared eight routinely employed immunoassay sets for the determination of MUC1 mucins in the serum: six closed automated systems (AxSYM, Centaur, ECi Vitros, Elecsys 2010, Immulite 2000 and Kryptor), and two IRMA kits (ELSA CIS and IRMA-mat Byk-Sangtec). Using all analytical systems, we measured identical groups of clinical samples complete with selected calibrator and control samples. The repeatability of measurements (presented as coefficients of variation) ranged from 0.7% (Kryptor) to 6.9% (Immulite 2000). Even though the cut-off values differ among various systems, no similar clinical efficacy appears to be attained. In the region of cut-off values, the highest specificity that was set as a standard was found for the AxSYM analyser, while the sensitivity was highest for the Elecsys 2010. Data from Bland-Altman differential plots suggest the presence of significant individual differences among individual samples, mainly in the region of high concentrations of MUC1 mucins. The parameters of Passing-Bablok regression show significant systematic differences between some of the analytical systems as well as an increase of the differences with increasing MUC1 mucin concentrations. The effect of the combination of antibodies used on the extent of differences among results obtained with individual systems is more obvious than the effect of the matrix of analysed materials. 
540 |a Copyright © 2003 by Walter de Gruyter GmbH & Co. KG 
690 7 |a Medical equipment & techniques  |2 nationallicence 
690 7 |a Medical diagnosis  |2 nationallicence 
690 7 |a Diseases & disorders  |2 nationallicence 
700 1 |a Stern  |D Petr  |4 aut 
700 1 |a Bartos  |D Vladimir  |4 aut 
700 1 |a Vavrova  |D Jaroslava  |4 aut 
700 1 |a Bezdickova  |D Drahomira  |4 aut 
700 1 |a Pechova  |D Martina  |4 aut 
700 1 |a Uhrova  |D Jana  |4 aut 
700 1 |a Friedecky  |D Bedrich  |4 aut 
700 1 |a Sprongl  |D Ludek  |4 aut 
700 1 |a Zima  |D Tomas  |4 aut 
700 1 |a Palicka  |D Vladimir  |4 aut 
773 0 |t Clinical Chemistry and Laboratory Medicine  |d Walter de Gruyter  |g 41/8(2003-08-07), 1087-1094  |x 1434-6621  |q 41:8<1087  |1 2003  |2 41  |o cclm 
856 4 0 |u https://doi.org/10.1515/CCLM.2003.168  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1515/CCLM.2003.168  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Stern  |D Petr  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Bartos  |D Vladimir  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Vavrova  |D Jaroslava  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Bezdickova  |D Drahomira  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Pechova  |D Martina  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Uhrova  |D Jana  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Friedecky  |D Bedrich  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Sprongl  |D Ludek  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Zima  |D Tomas  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Palicka  |D Vladimir  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Clinical Chemistry and Laboratory Medicine  |d Walter de Gruyter  |g 41/8(2003-08-07), 1087-1094  |x 1434-6621  |q 41:8<1087  |1 2003  |2 41  |o cclm 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter