Modulare Hüftrevisionsschäfte auf Titanbasis - Einfluß und Optimierung des Steifigkeitsverhaltens
Gespeichert in:
Verfasser / Beitragende:
The Modular Hip Revision Stem Made of Titanium Alloy (MRP-Titan Revision Stem) - Influence and Optimisation of Bending Stiffness / [U Holzwarth, G Zeiler, F Lintner, A Schuh]
Ort, Verlag, Jahr:
2004
Enthalten in:
Biomedizinische Technik/Biomedical Engineering, 49/7-8(2004-08-01), 216-221
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 378885693 | ||
| 003 | CHVBK | ||
| 005 | 20180305123442.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 161128e20040801xx s 000 0 ger | ||
| 024 | 7 | 0 | |a 10.1515/BMT.2004.040 |2 doi |
| 035 | |a (NATIONALLICENCE)gruyter-10.1515/BMT.2004.040 | ||
| 245 | 0 | 0 | |a Modulare Hüftrevisionsschäfte auf Titanbasis - Einfluß und Optimierung des Steifigkeitsverhaltens |h [Elektronische Daten] |c The Modular Hip Revision Stem Made of Titanium Alloy (MRP-Titan Revision Stem) - Influence and Optimisation of Bending Stiffness / [U Holzwarth, G Zeiler, F Lintner, A Schuh] |
| 520 | 3 | |a Der MRP-Titan-Revisionsschaft hat sich als sehr erfolgreiches Implantatsystem in der Revisionsendoprothetik des Hüftgelenkes bewährt. Mit diesem Revisionssystem wurden in Studien gute und sehr gute klinische Ergebnisse und hervorragende radiologische Resultate mit spontaner Auffüllung von Femurdefekten publiziert. Die Beobachtung, daß bei Schaftdurchmessern von mehr als 17 mm eine Atrophie des proximalen Femurs zu verzeichnen war, veranlaßte uns, Steifigkeitsmessungen des MRP-Titan-Revisionsschaftes unterschiedlicher Standarddurchmesser vorzunehmen. Zur Bestimmung des statischen Biegeverhaltens wurde der MRP-Titan- Revisionsschaft unter axialer Beanspruchung entsprechend der Eulerschen Knickfälle geprüft. Die Untersuchungen wurden mit dem monoaxialen servohydraulischen System MTS 810 durchgeführt. Es zeigte sich, daß die Durchbiegung ab einem Schaftdurchmesser von 18 mm überproportional abnahm, was direkt mit einer höheren Steifigkeit des Schaftes korreliert. Sowohl geometrische Optimierung als auch Werkstoffvariation ermöglichen die Einstellung eines konstanten ISD-Faktors für das modulare Revisionsimplantatsystem MRP-Titan. Schlußfolgerung: Mit dem MRP-Titan-Revisionsschaft ist ein zuverlässiges Implantat in der Revisionsendoprothetik an die Hand gegeben. Die klinische Beobachtung einer proximalen Femuratrophie bei Schaftdurchmessern von mehr als 17 mm konnte mit einem entsprechenden exponentiellen Anstieg der Steifigkeit über die Bestimmung der Durchbiegung und des ISD-Faktors bestätigt werden. Ziel weiterführender Entwicklung wird es sein, durch konstruktive und/oder werkstoffkundliche Maßnahmen (z. B. alternative Legierungen: Ti- Mo15, TiNb13Zr13, TiMo12Zr6Fe2) die Steifigkeit des MRP-Titan- Revisionsschaftes bei größeren Schaftdurchmessern zu reduzieren. The MRP-Titan Revision stem has proved to be a highly successful implant system for revision arthroplasty of the hip. Good and excellent clinical and radiological results with spontaneous filling of bony defects have been reported, The observation of atrophy of the proximal femur associated with stem diameters > 17mm prompted us to examine the bending stiffness of stems of various diameters. To determine their static bending characteristics, the stems were tested under axial pressure loads in accordance with Euler's buckling case. Dynamic tests were performed with the mono-axial servohydraulic test equipment MTS 810. From a stem diameter of 18 mm upwards, deflection of the stem under loading decreased disproportionately, in direct correlation with the stem stiffness. By optimising the geometry and varying the alloy it is possible to obtain a constant ISD factor for the modular MRP-Titan revision stem Conclusion: The MRP-Titan revision stem is a reliable implant system for revision arthroplasty of the hip. Clinical findings of atrophy of the proximal femur associated with stem diameters >17 mm was found to be correlated with a disproportionate increase in bending stiffness. The aim of further developments will be to reduce the stiffness of larger- diameter stems by making changes to the design and/or to the alloy (Ti15Mo,Ti13Nb13Zr,Ti12Mo6Zr2Fe2). | |
| 540 | |a © Walter de Gruyter | ||
| 690 | 7 | |a Hüftendoprothese |2 nationallicence | |
| 690 | 7 | |a modularer Revisionsschaft |2 nationallicence | |
| 690 | 7 | |a MRP-Titan |2 nationallicence | |
| 690 | 7 | |a Schaftsteifigkeit |2 nationallicence | |
| 690 | 7 | |a Eulerscher Knickfall |2 nationallicence | |
| 690 | 7 | |a Lysesaumbildung |2 nationallicence | |
| 690 | 7 | |a zementfreie Revision |2 nationallicence | |
| 690 | 7 | |a Knochenanwachsverhalten |2 nationallicence | |
| 690 | 7 | |a Hip endoprosthesis |2 nationallicence | |
| 690 | 7 | |a Modular revision stem |2 nationallicence | |
| 690 | 7 | |a MRP-Titan |2 nationallicence | |
| 690 | 7 | |a Stem stiffness |2 nationallicence | |
| 690 | 7 | |a Euler's buckling case |2 nationallicence | |
| 690 | 7 | |a Radiolucent lines |2 nationallicence | |
| 690 | 7 | |a Cement-free revision |2 nationallicence | |
| 690 | 7 | |a Bone growth |2 nationallicence | |
| 700 | 1 | |a Holzwarth |D U. |u Med-Titan, Erlangen. |4 aut | |
| 700 | 1 | |a Zeiler |D G. |u Orthopädische Klinik Rummelsberg, Schwarzenbruck. |4 aut | |
| 700 | 1 | |a Lintner |D F. |u Pathologisch-bakteriologisches Institut Universität Wien, Wien. |4 aut | |
| 700 | 1 | |a Schuh |D A. |u Orthopädische Klinik Rummelsberg, Schwarzenbruck. |4 aut | |
| 773 | 0 | |t Biomedizinische Technik/Biomedical Engineering |d Walter de Gruyter |g 49/7-8(2004-08-01), 216-221 |x 0013-5585 |q 49:7-8<216 |1 2004 |2 49 |o bmte | |
| 856 | 4 | 0 | |u https://doi.org/10.1515/BMT.2004.040 |q text/html |z Onlinezugriff via DOI |
| 908 | |D 1 |a research article |2 jats | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1515/BMT.2004.040 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Holzwarth |D U. |u Med-Titan, Erlangen |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Zeiler |D G. |u Orthopädische Klinik Rummelsberg, Schwarzenbruck |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Lintner |D F. |u Pathologisch-bakteriologisches Institut Universität Wien, Wien |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Schuh |D A. |u Orthopädische Klinik Rummelsberg, Schwarzenbruck |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Biomedizinische Technik/Biomedical Engineering |d Walter de Gruyter |g 49/7-8(2004-08-01), 216-221 |x 0013-5585 |q 49:7-8<216 |1 2004 |2 49 |o bmte | ||
| 900 | 7 | |b CC0 |u http://creativecommons.org/publicdomain/zero/1.0 |2 nationallicence | |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-gruyter | ||