Modulare Hüftrevisionsschäfte auf Titanbasis - Einfluß und Optimierung des Steifigkeitsverhaltens

Verfasser / Beitragende:
The Modular Hip Revision Stem Made of Titanium Alloy (MRP-Titan Revision Stem) - Influence and Optimisation of Bending Stiffness / [U Holzwarth, G Zeiler, F Lintner, A Schuh]
Ort, Verlag, Jahr:
2004
Enthalten in:
Biomedizinische Technik/Biomedical Engineering, 49/7-8(2004-08-01), 216-221
Format:
Artikel (online)
ID: 378885693
LEADER caa a22 4500
001 378885693
003 CHVBK
005 20180305123442.0
007 cr unu---uuuuu
008 161128e20040801xx s 000 0 ger
024 7 0 |a 10.1515/BMT.2004.040  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1515/BMT.2004.040 
245 0 0 |a Modulare Hüftrevisionsschäfte auf Titanbasis - Einfluß und Optimierung des Steifigkeitsverhaltens  |h [Elektronische Daten]  |c The Modular Hip Revision Stem Made of Titanium Alloy (MRP-Titan Revision Stem) - Influence and Optimisation of Bending Stiffness / [U Holzwarth, G Zeiler, F Lintner, A Schuh] 
520 3 |a Der MRP-Titan-Revisionsschaft hat sich als sehr erfolgreiches Implantatsystem in der Revisionsendoprothetik des Hüftgelenkes bewährt. Mit diesem Revisionssystem wurden in Studien gute und sehr gute klinische Ergebnisse und hervorragende radiologische Resultate mit spontaner Auffüllung von Femurdefekten publiziert. Die Beobachtung, daß bei Schaftdurchmessern von mehr als 17 mm eine Atrophie des proximalen Femurs zu verzeichnen war, veranlaßte uns, Steifigkeitsmessungen des MRP-Titan-Revisionsschaftes unterschiedlicher Standarddurchmesser vorzunehmen. Zur Bestimmung des statischen Biegeverhaltens wurde der MRP-Titan- Revisionsschaft unter axialer Beanspruchung entsprechend der Eulerschen Knickfälle geprüft. Die Untersuchungen wurden mit dem monoaxialen servohydraulischen System MTS 810 durchgeführt. Es zeigte sich, daß die Durchbiegung ab einem Schaftdurchmesser von 18 mm überproportional abnahm, was direkt mit einer höheren Steifigkeit des Schaftes korreliert. Sowohl geometrische Optimierung als auch Werkstoffvariation ermöglichen die Einstellung eines konstanten ISD-Faktors für das modulare Revisionsimplantatsystem MRP-Titan. Schlußfolgerung: Mit dem MRP-Titan-Revisionsschaft ist ein zuverlässiges Implantat in der Revisionsendoprothetik an die Hand gegeben. Die klinische Beobachtung einer proximalen Femuratrophie bei Schaftdurchmessern von mehr als 17 mm konnte mit einem entsprechenden exponentiellen Anstieg der Steifigkeit über die Bestimmung der Durchbiegung und des ISD-Faktors bestätigt werden. Ziel weiterführender Entwicklung wird es sein, durch konstruktive und/oder werkstoffkundliche Maßnahmen (z. B. alternative Legierungen: Ti- Mo15, TiNb13Zr13, TiMo12Zr6Fe2) die Steifigkeit des MRP-Titan- Revisionsschaftes bei größeren Schaftdurchmessern zu reduzieren. The MRP-Titan Revision stem has proved to be a highly successful implant system for revision arthroplasty of the hip. Good and excellent clinical and radiological results with spontaneous filling of bony defects have been reported, The observation of atrophy of the proximal femur associated with stem diameters > 17mm prompted us to examine the bending stiffness of stems of various diameters. To determine their static bending characteristics, the stems were tested under axial pressure loads in accordance with Euler's buckling case. Dynamic tests were performed with the mono-axial servohydraulic test equipment MTS 810. From a stem diameter of 18 mm upwards, deflection of the stem under loading decreased disproportionately, in direct correlation with the stem stiffness. By optimising the geometry and varying the alloy it is possible to obtain a constant ISD factor for the modular MRP-Titan revision stem Conclusion: The MRP-Titan revision stem is a reliable implant system for revision arthroplasty of the hip. Clinical findings of atrophy of the proximal femur associated with stem diameters >17 mm was found to be correlated with a disproportionate increase in bending stiffness. The aim of further developments will be to reduce the stiffness of larger- diameter stems by making changes to the design and/or to the alloy (Ti15Mo,Ti13Nb13Zr,Ti12Mo6Zr2Fe2). 
540 |a © Walter de Gruyter 
690 7 |a Hüftendoprothese  |2 nationallicence 
690 7 |a modularer Revisionsschaft  |2 nationallicence 
690 7 |a MRP-Titan  |2 nationallicence 
690 7 |a Schaftsteifigkeit  |2 nationallicence 
690 7 |a Eulerscher Knickfall  |2 nationallicence 
690 7 |a Lysesaumbildung  |2 nationallicence 
690 7 |a zementfreie Revision  |2 nationallicence 
690 7 |a Knochenanwachsverhalten  |2 nationallicence 
690 7 |a Hip endoprosthesis  |2 nationallicence 
690 7 |a Modular revision stem  |2 nationallicence 
690 7 |a MRP-Titan  |2 nationallicence 
690 7 |a Stem stiffness  |2 nationallicence 
690 7 |a Euler's buckling case  |2 nationallicence 
690 7 |a Radiolucent lines  |2 nationallicence 
690 7 |a Cement-free revision  |2 nationallicence 
690 7 |a Bone growth  |2 nationallicence 
700 1 |a Holzwarth  |D U.  |u Med-Titan, Erlangen.  |4 aut 
700 1 |a Zeiler  |D G.  |u Orthopädische Klinik Rummelsberg, Schwarzenbruck.  |4 aut 
700 1 |a Lintner  |D F.  |u Pathologisch-bakteriologisches Institut Universität Wien, Wien.  |4 aut 
700 1 |a Schuh  |D A.  |u Orthopädische Klinik Rummelsberg, Schwarzenbruck.  |4 aut 
773 0 |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/7-8(2004-08-01), 216-221  |x 0013-5585  |q 49:7-8<216  |1 2004  |2 49  |o bmte 
856 4 0 |u https://doi.org/10.1515/BMT.2004.040  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1515/BMT.2004.040  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Holzwarth  |D U.  |u Med-Titan, Erlangen  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Zeiler  |D G.  |u Orthopädische Klinik Rummelsberg, Schwarzenbruck  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Lintner  |D F.  |u Pathologisch-bakteriologisches Institut Universität Wien, Wien  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Schuh  |D A.  |u Orthopädische Klinik Rummelsberg, Schwarzenbruck  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/7-8(2004-08-01), 216-221  |x 0013-5585  |q 49:7-8<216  |1 2004  |2 49  |o bmte 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter