Zentrale Zugseilsysteme - vollautomatische, kontinuierliche Kallusdistraktion zur Behandlung langstreckiger Knochendefekte

Verfasser / Beitragende:
Bone Transport System with a Central Cable - Fully Automatic, Continuous Distraction Osteogenesis for the Treatment of Large Bone Defects / [R Baumgart, S Hinterwimmer, M Krammer, W Mutschler]
Ort, Verlag, Jahr:
2004
Enthalten in:
Biomedizinische Technik/Biomedical Engineering, 49/7-8(2004-08-01), 202-207
Format:
Artikel (online)
ID: 378885723
LEADER caa a22 4500
001 378885723
003 CHVBK
005 20180305123442.0
007 cr unu---uuuuu
008 161128e20040801xx s 000 0 ger
024 7 0 |a 10.1515/BMT.2004.038  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1515/BMT.2004.038 
245 0 0 |a Zentrale Zugseilsysteme - vollautomatische, kontinuierliche Kallusdistraktion zur Behandlung langstreckiger Knochendefekte  |h [Elektronische Daten]  |c Bone Transport System with a Central Cable - Fully Automatic, Continuous Distraction Osteogenesis for the Treatment of Large Bone Defects / [R Baumgart, S Hinterwimmer, M Krammer, W Mutschler] 
520 3 |a Die Kallusdistraktion durch Segmenttransport dient dem Ausgleich von Knochendefekten oder Knochenverlusten. Die Hauptfragmente werden meist von extern stabilisiert, ein intermediäres Knochensegment wird abgelöst und mit einer Geschwindigkeit von ca. 1 mm/Tag durch den Defekt gezogen. In dem ständig größer werdenden Osteotomiespalt bildet sich ein hochwertiges Knochenregenerat. Nachteilig ist, daß die Stabilisatoren des Verschiebesegments über die gleiche Länge, wie sie der Knochendefekt mißt, die Weichteile durchschneiden, was häufig zu schmerzhaften Pininfektionen mit Folgeoperationen sowie einer unschönen Narbenbildung führt. Mit dem in München entwickelten automatischen, motorgetriebenen Segmenttransport mit nur einem einzigen, zentral verlaufenden Zugseil wird der Querverzug von Pins durch die Weichteile vollständig vermieden. Grundsätzlich kann ein derartiges "zentrales Zugseilsystem" mit jedem externen Fixateur kombiniert werden, da die zu implantierenden Teile unabhängig von diesem Fixateur eingebracht werden. Der in schonender Technik durchführbare operative Eingriff mit Ablösung des Transportsegments, Verankerung des Zugseilsystems und Stabilisierung der Hauptfragmente erfordert zahlreiche Spezialwerkzeuge. Der Distraktionsverlauf führt zu deutlich reduzierten Weichteilirritationen und Schmerzen. Pininfektionen sind selten, so daß der Umstieg auf ein internes Stabilisationssystem nach Abschluß des Segmenttransports risikoarm durchgeführt werden kann. In dem hier vorliegenden Beitrag werden die technischen Besonderheiten des Stabilisierungssystems sowie des Transport- und Steuersystems detailliert beschrieben, und der klinische Einsatz wird anhand eines Patientenbeispiels vorgestellt. Distraction osteogenesis involving bone transport enables the reconstruction of large bone defects. The main bone fragments are usually stablilised externally, an intermediate bone segment is separated and moved through the defect at a rate of about l mm/day. New high-quality bone is built up in the constantly enlarging osteotomy gap. A major problem associated with the method is the fact that the fixation pins are also moved over the same distance, and cut through the soft tissue, often resulting in painful pin tract infections and ugly scars. An automatic motorized bone transport system employing a single central cable now eliminates this problem. The system can be combined with any external fixateur, since the relevant implanted parts for bone transport are independent of the external stabilizer. The surgical procedure, which is easy on the patient, consists of bone segment separation, central cable fixation, and stabilisation of the main fragments, and requires the use of numerous special tools. The distraction itself results in significantly less soft tissue irritation and pain. Pin tract infections are rare, so that changeover to internal fixation after completion of bone transport carries little risk of infection. This article details the technical features of the stabilizing system and the transport and the control systems, and describes the clinical application in a patient. 
540 |a © Walter de Gruyter 
690 7 |a Kallusdistraktion  |2 nationallicence 
690 7 |a Segmenttransport  |2 nationallicence 
690 7 |a Zugseilsystem  |2 nationallicence 
690 7 |a Knochendefekt  |2 nationallicence 
690 7 |a Distraction osteogenesis  |2 nationallicence 
690 7 |a Bone transport  |2 nationallicence 
690 7 |a Cable system  |2 nationallicence 
690 7 |a Bone defect  |2 nationallicence 
700 1 |a Baumgart  |D R.  |u Klinikum der Universität München, Chirurgische Klinik und Poliklinik.  |4 aut 
700 1 |a Hinterwimmer  |D S.  |u Klinikum der Universität München, Chirurgische Klinik und Poliklinik.  |4 aut 
700 1 |a Krammer  |D M.  |u Klinikum der Universität München, Chirurgische Klinik und Poliklinik.  |4 aut 
700 1 |a Mutschler  |D W.  |u Klinikum der Universität München, Chirurgische Klinik und Poliklinik.  |4 aut 
773 0 |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/7-8(2004-08-01), 202-207  |x 0013-5585  |q 49:7-8<202  |1 2004  |2 49  |o bmte 
856 4 0 |u https://doi.org/10.1515/BMT.2004.038  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1515/BMT.2004.038  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Baumgart  |D R.  |u Klinikum der Universität München, Chirurgische Klinik und Poliklinik  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Hinterwimmer  |D S.  |u Klinikum der Universität München, Chirurgische Klinik und Poliklinik  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Krammer  |D M.  |u Klinikum der Universität München, Chirurgische Klinik und Poliklinik  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Mutschler  |D W.  |u Klinikum der Universität München, Chirurgische Klinik und Poliklinik  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/7-8(2004-08-01), 202-207  |x 0013-5585  |q 49:7-8<202  |1 2004  |2 49  |o bmte 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter