Untersuchung von Schlafstörungen um Hochfrequenz-Sendeanlagen

Verfasser / Beitragende:
Investigation of Sleep Disorders in the Vicinity of RF Transmitters / [N Leitgeb, J Schröttner, R Cech, R Kerbl]
Ort, Verlag, Jahr:
2004
Enthalten in:
Biomedizinische Technik/Biomedical Engineering, 49/7-8(2004-08-01), 186-193
Format:
Artikel (online)
ID: 378885731
LEADER caa a22 4500
001 378885731
003 CHVBK
005 20180305123442.0
007 cr unu---uuuuu
008 161128e20040801xx s 000 0 ger
024 7 0 |a 10.1515/BMT.2004.035  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1515/BMT.2004.035 
245 0 0 |a Untersuchung von Schlafstörungen um Hochfrequenz-Sendeanlagen  |h [Elektronische Daten]  |c Investigation of Sleep Disorders in the Vicinity of RF Transmitters / [N Leitgeb, J Schröttner, R Cech, R Kerbl] 
520 3 |a Zur Untersuchung eines potentiellen Einflusses von hochfrequenten elektromagnetischen Feldern von Sendeanlagen auf die Schlafqualität von elektrosensiblen Anrainern wird ein neuartiges Studiendesign vorgestellt. In einer Doppelblind-Crossover-Feldstudie wird die Auswirkung einer Vor-Ort-Abschirmung statt einer zusätzlichen Exposition untersucht. Zur zuverlässigeren Differenzierung der Schlafqualität werden Polysomnographie-Parameter durch zusätzliche Meßgrößen ergänzt. Die Machbarkeitsstudie zeigte, daß die Überprüfung der Rohdaten der Schlafaufzeichnung und eine Korrektur der Ergebnisse der Auswertungssoftware durch visuelle Befundung der Polysomnographie-Aufzeichnungen unverzichtbar sind. Die Langzeit-frequenzselektive Messung der HF-Immissionen ergab, daß die Exposition sowohl während einer Nacht als auch zwischen den Nächten sehr stark variieren kann. Die Variationen können größer als die Größe des vom Mobilfunk stammenden Immissionsanteils sein. Es dominierten meist die Anteile im UKW-Radiofrequenzband im Vergleich zu den Mobilfunkanteilen. Für eine zuverlässige Interpretation der Ergebnisse insbesonders in Hinblick auf eine Beurteilung der Mobilfunk-Immission ist daher eine kontinuierliche breitbandige Erfassung der HF-Immission unverzichtbar. Die Ergebnisse zeigen, daß einfache Schlaferfassungssysteme, die nur auf der Einkanal-EEG-Auswertung beruhen und keine Kontrolle der Rohdaten zulassen, für Schlafstudien ungeeignet sind. To investigate the potential impact of RF electromagnetic fields of transmitters on the sleep quality of nearby residents, a new study design is presented. In a double- blind crossover field study the effect of on-site shielding, rather than of additional exposure, is investigated. For improved sleep quality differentiation the polysomnographic parameters are expanded by additional parameters. The feasibility study showed that checking the raw data and correcting the software-generated results by visual reading of the polysomnographic recordings is essential. Long-term RF measurement showed that exposure may vary considerably throughout the night, as well as from one night to the next. This variation may be greater than the GSM contribution itself. Mostly, the contributions of USW radio frequency fields dominated over GSM. Thus, continuous broadband RF recording is required for reliable interpretation of the results, in particular with regard to the potential role of mobile telephony emissions. Results show that simple sleep monitoring systems based on single-channel EEG analysis without acces to original biosignals are not adequate for sleep studies. 
540 |a © Walter de Gruyter 
690 7 |a Elektrosensibilität  |2 nationallicence 
690 7 |a Mobilfunk  |2 nationallicence 
690 7 |a Schlafstudie  |2 nationallicence 
690 7 |a Qualitätskriterien  |2 nationallicence 
690 7 |a Electromagnetic hypersensitivity  |2 nationallicence 
690 7 |a Cellular telephony  |2 nationallicence 
690 7 |a Sleep study  |2 nationallicence 
690 7 |a Quality criteria  |2 nationallicence 
700 1 |a Leitgeb  |D N.  |u Institut für Krankenhaustechnik, Technische Universität Graz.  |4 aut 
700 1 |a Schröttner  |D J.  |u Institut für Krankenhaustechnik, Technische Universität Graz.  |4 aut 
700 1 |a Cech  |D R.  |u Institut für Krankenhaustechnik, Technische Universität Graz.  |4 aut 
700 1 |a Kerbl  |D R.  |u Universitätsklinik für Kinder- und Jugendheilkunde der Medizin, Universität Graz.  |4 aut 
773 0 |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/7-8(2004-08-01), 186-193  |x 0013-5585  |q 49:7-8<186  |1 2004  |2 49  |o bmte 
856 4 0 |u https://doi.org/10.1515/BMT.2004.035  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1515/BMT.2004.035  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Leitgeb  |D N.  |u Institut für Krankenhaustechnik, Technische Universität Graz  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Schröttner  |D J.  |u Institut für Krankenhaustechnik, Technische Universität Graz  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Cech  |D R.  |u Institut für Krankenhaustechnik, Technische Universität Graz  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kerbl  |D R.  |u Universitätsklinik für Kinder- und Jugendheilkunde der Medizin, Universität Graz  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/7-8(2004-08-01), 186-193  |x 0013-5585  |q 49:7-8<186  |1 2004  |2 49  |o bmte 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter