Multicenter evaluation of a new immunoassay for procalcitonin measurement on the Kryptor® System

Verfasser / Beitragende:
[Gerald Steinbach, Bettina Rau, Anne-Lise Debard, Jean-François Javourez, Jacques Bienvenu, Antonio Ponzio, Andrea Bonfà, Walter Hubl, Thomas Demant, W.-R. Külpmann, Jana Buchholz, Gerhard Schumann]
Ort, Verlag, Jahr:
2004
Enthalten in:
Clinical Chemistry and Laboratory Medicine, 42/4(2004-04-05), 440-449
Format:
Artikel (online)
ID: 37889059X
LEADER caa a22 4500
001 37889059X
003 CHVBK
005 20180305123453.0
007 cr unu---uuuuu
008 161128e20040405xx s 000 0 eng
024 7 0 |a 10.1515/CCLM.2004.077  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1515/CCLM.2004.077 
245 0 0 |a Multicenter evaluation of a new immunoassay for procalcitonin measurement on the Kryptor® System  |h [Elektronische Daten]  |c [Gerald Steinbach, Bettina Rau, Anne-Lise Debard, Jean-François Javourez, Jacques Bienvenu, Antonio Ponzio, Andrea Bonfà, Walter Hubl, Thomas Demant, W.-R. Külpmann, Jana Buchholz, Gerhard Schumann] 
520 3 |a We compared the manually performed LUMItest® procalcitonin (PCT) assay with the newly developed fully mechanized Kryptor® PCT assay and determined the essential assay characteristics of this assay. The new Kryptor® PCT assay was evaluated according to modified NCCLS EP-10/EP-6 protocols in five different laboratories. Samples from 696 patients were assayed using the original LUMItest® PCT assay and the new Kryptor® PCT assay. Possible interference by hemoglobin, triglycerides and bilirubin was evaluated by spiking patient plasma with the appropriate substances. The functional assay sensitivity (FAS) was determined by analyzing samples with low PCT concentrations. The FAS of the new Kryptor® PCT assay was 0.04 ng/ml and the imprecision within- and between-series below 5% and below 10%, respectively. Within the smallest range of determination, from 0.3 ng/ml to 50 ng/ml, common to the LUMItest® PCT assay (x) and the Kryptor® PCT assay (y) the values correlated well: y=0.64+0.94x, s.xy=2.78 ng/ml. The performance characteristics of the Kryptor® PCT assay are fully compatible with the intended clinical use. The assay allows determination of PCT in a turnaround time (TAT) of about 20 minutes and thus is adequate for STAT analyses. 
540 |a Copyright © 2004 by Walter de Gruyter GmbH & Co. KG 
690 7 |a Medical equipment & techniques  |2 nationallicence 
690 7 |a Medical diagnosis  |2 nationallicence 
690 7 |a Diseases & disorders  |2 nationallicence 
700 1 |a Steinbach  |D Gerald  |4 aut 
700 1 |a Rau  |D Bettina  |4 aut 
700 1 |a Debard  |D Anne-Lise  |4 aut 
700 1 |a Javourez  |D Jean-François  |4 aut 
700 1 |a Bienvenu  |D Jacques  |4 aut 
700 1 |a Ponzio  |D Antonio  |4 aut 
700 1 |a Bonfà  |D Andrea  |4 aut 
700 1 |a Hubl  |D Walter  |4 aut 
700 1 |a Demant  |D Thomas  |4 aut 
700 1 |a Külpmann  |D W.-R  |4 aut 
700 1 |a Buchholz  |D Jana  |4 aut 
700 1 |a Schumann  |D Gerhard  |4 aut 
773 0 |t Clinical Chemistry and Laboratory Medicine  |d Walter de Gruyter  |g 42/4(2004-04-05), 440-449  |x 1434-6621  |q 42:4<440  |1 2004  |2 42  |o cclm 
856 4 0 |u https://doi.org/10.1515/CCLM.2004.077  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1515/CCLM.2004.077  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Steinbach  |D Gerald  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Rau  |D Bettina  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Debard  |D Anne-Lise  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Javourez  |D Jean-François  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Bienvenu  |D Jacques  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ponzio  |D Antonio  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Bonfà  |D Andrea  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Hubl  |D Walter  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Demant  |D Thomas  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Külpmann  |D W.-R  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Buchholz  |D Jana  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Schumann  |D Gerhard  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Clinical Chemistry and Laboratory Medicine  |d Walter de Gruyter  |g 42/4(2004-04-05), 440-449  |x 1434-6621  |q 42:4<440  |1 2004  |2 42  |o cclm 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter