Evaluation of a new generation of plastic evacuated blood-collection tubes in clinical chemistry, therapeutic drug monitoring, hormone and trace metal analysis
Gespeichert in:
Verfasser / Beitragende:
[Jean-Marie Boeynaems, Anne De Leener, Barbara Dessars, Hector Rodriguez Villa-Lobos, Jean-Claude Aubry, Frédéric Cotton, Philippe Thiry]
Ort, Verlag, Jahr:
2004
Enthalten in:
Clinical Chemistry and Laboratory Medicine, 42/1(2004-02-16), 67-71
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 378897837 | ||
| 003 | CHVBK | ||
| 005 | 20180305123510.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 161128e20040216xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1515/CCLM.2004.013 |2 doi |
| 035 | |a (NATIONALLICENCE)gruyter-10.1515/CCLM.2004.013 | ||
| 245 | 0 | 0 | |a Evaluation of a new generation of plastic evacuated blood-collection tubes in clinical chemistry, therapeutic drug monitoring, hormone and trace metal analysis |h [Elektronische Daten] |c [Jean-Marie Boeynaems, Anne De Leener, Barbara Dessars, Hector Rodriguez Villa-Lobos, Jean-Claude Aubry, Frédéric Cotton, Philippe Thiry] |
| 520 | 3 | |a Polyethylene terephthalate (PET) tubes have several advantages over glass tubes: they are unbreakable, lighter and more easily disposed of. Despite a steady increase in their use and an expansion of the range of available tubes, few studies validating their use have been published in the literature. This paper describes the various studies that have been performed to compare VENOJECT glass, VENOSAFE PET and VENOSAFE PET/heparin tubes for the assay of a panel of analytes in routine clinical chemistry, immunochemistry, hormone and tumor marker analysis and trace metal determination. These studies demonstrate that VENOSAFE PET tubes are a suitable alternative to glass tubes. | |
| 540 | |a Copyright © 2004 by Walter de Gruyter GmbH & Co. KG | ||
| 690 | 7 | |a Medical equipment & techniques |2 nationallicence | |
| 690 | 7 | |a Medical diagnosis |2 nationallicence | |
| 690 | 7 | |a Diseases & disorders |2 nationallicence | |
| 700 | 1 | |a Boeynaems |D Jean-Marie |4 aut | |
| 700 | 1 | |a Leener |D Anne De |4 aut | |
| 700 | 1 | |a Dessars |D Barbara |4 aut | |
| 700 | 1 | |a Villa-Lobos |D Hector Rodriguez |4 aut | |
| 700 | 1 | |a Aubry |D Jean-Claude |4 aut | |
| 700 | 1 | |a Cotton |D Frédéric |4 aut | |
| 700 | 1 | |a Thiry |D Philippe |4 aut | |
| 773 | 0 | |t Clinical Chemistry and Laboratory Medicine |d Walter de Gruyter |g 42/1(2004-02-16), 67-71 |x 1434-6621 |q 42:1<67 |1 2004 |2 42 |o cclm | |
| 856 | 4 | 0 | |u https://doi.org/10.1515/CCLM.2004.013 |q text/html |z Onlinezugriff via DOI |
| 908 | |D 1 |a research article |2 jats | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1515/CCLM.2004.013 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Boeynaems |D Jean-Marie |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Leener |D Anne De |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Dessars |D Barbara |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Villa-Lobos |D Hector Rodriguez |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Aubry |D Jean-Claude |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Cotton |D Frédéric |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Thiry |D Philippe |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Clinical Chemistry and Laboratory Medicine |d Walter de Gruyter |g 42/1(2004-02-16), 67-71 |x 1434-6621 |q 42:1<67 |1 2004 |2 42 |o cclm | ||
| 900 | 7 | |b CC0 |u http://creativecommons.org/publicdomain/zero/1.0 |2 nationallicence | |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-gruyter | ||