Analytical goals for coagulation tests based on biological variation

Verfasser / Beitragende:
[Yui Wada, Masako Kurihara, Mitsuko Toyofuku, Minako Kawamura, Hiroko Iida, Yuzou Kayamori, Sachiko Kinoshita, Naotaka Hamasaki]
Ort, Verlag, Jahr:
2004
Enthalten in:
Clinical Chemistry and Laboratory Medicine, 42/1(2004-02-16), 79-83
Format:
Artikel (online)
ID: 37889787X
LEADER caa a22 4500
001 37889787X
003 CHVBK
005 20180305123510.0
007 cr unu---uuuuu
008 161128e20040216xx s 000 0 eng
024 7 0 |a 10.1515/CCLM.2004.015  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1515/CCLM.2004.015 
245 0 0 |a Analytical goals for coagulation tests based on biological variation  |h [Elektronische Daten]  |c [Yui Wada, Masako Kurihara, Mitsuko Toyofuku, Minako Kawamura, Hiroko Iida, Yuzou Kayamori, Sachiko Kinoshita, Naotaka Hamasaki] 
520 3 |a Allowable imprecision and bias reference limits for laboratory data can be calculated based on measurements of biological variation. Although biological variation of clinical chemical data has been reported from many laboratories, there have been few reports of biological variation in coagulation tests. In this study, we calculated the biological variation of 13 coagulation tests in the clinical laboratory of Kyushu University Hospital and determined allowable imprecision and bias limits of variation. The participating subjects were 17 healthy individuals: three males and two females in their 20s, two males and two females in their 30s, one male and four females in their 40s, and two males and one female in their 50s. Monthly measurements were performed before breakfast 12 times from June 2001 to May 2002 and allowable imprecision and bias limits were calculated. Taken together with coefficient of variation of control plasma used in daily laboratory work at the hospital, the allowable imprecision limits of intra-laboratory variation determined in this study appear to be in attainable ranges. 
540 |a Copyright (c) 2004 by Walter de Gruyter GmbH & Co. KG 
690 7 |a Medical equipment & techniques  |2 nationallicence 
690 7 |a Medical diagnosis  |2 nationallicence 
690 7 |a Diseases & disorders  |2 nationallicence 
700 1 |a Wada  |D Yui  |4 aut 
700 1 |a Kurihara  |D Masako  |4 aut 
700 1 |a Toyofuku  |D Mitsuko  |4 aut 
700 1 |a Kawamura  |D Minako  |4 aut 
700 1 |a Iida  |D Hiroko  |4 aut 
700 1 |a Kayamori  |D Yuzou  |4 aut 
700 1 |a Kinoshita  |D Sachiko  |4 aut 
700 1 |a Hamasaki  |D Naotaka  |4 aut 
773 0 |t Clinical Chemistry and Laboratory Medicine  |d Walter de Gruyter  |g 42/1(2004-02-16), 79-83  |x 1434-6621  |q 42:1<79  |1 2004  |2 42  |o cclm 
856 4 0 |u https://doi.org/10.1515/CCLM.2004.015  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1515/CCLM.2004.015  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Wada  |D Yui  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kurihara  |D Masako  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Toyofuku  |D Mitsuko  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kawamura  |D Minako  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Iida  |D Hiroko  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kayamori  |D Yuzou  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kinoshita  |D Sachiko  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Hamasaki  |D Naotaka  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Clinical Chemistry and Laboratory Medicine  |d Walter de Gruyter  |g 42/1(2004-02-16), 79-83  |x 1434-6621  |q 42:1<79  |1 2004  |2 42  |o cclm 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 