<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">378898280</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123511.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20041201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1515/CCLM.2004.260</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.1515/CCLM.2004.260</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Analysis of inflammatory response in human plasma samples by an automated multicapillary electrophoresis system</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Anders Larsson, Lars-Olof Hansson]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A new automated multicapillary zone electrophoresis instrument with a new high-resolution (HR) buffer (Capillarys™ with HR buffer) for analysis of human plasma proteins was evaluated. Albumin, α1-antitrypsin, α1-acid glycoprotein, haptoglobin, fibrinogen, immunoglobulin (Ig)A, IgG and IgM were determined nephelometrically in 200 patient plasma samples. The same samples were then analyzed on the Capillarys™ system (Sebia, Paris, France). The albumin concentration from the nephelometric determination was used for quantification of the individual peaks in the capillary electrophoresis (CE) electropherogram. There was strong linear correlation between the nephelometric and electrophoretic determination of α1-antitrypsin (R2=0.906), α1-acid glycoprotein (R2=0.894) and haptoglobin (R2=0.913). There was also good correlation between the two determinations of γ-globulins (R2=0.883), while the correlation was weaker for fibrinogen (R2=0.377). The Capillarys™ instrument is a reliable system for plasma protein analysis, combining the advantages of full automation, good analytical performance and high throughput. The HR buffer in combination with albumin quantification allows the simultaneous quantification of inflammatory markers in plasma samples without the need for nephelometric determination of these proteins.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">©2004 by Walter de Gruyter Berlin New York</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Medical equipment &amp; techniques</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Medical diagnosis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Diseases &amp; disorders</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">agarose gel electrophoresis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">capillary electrophoresis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">human</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">inflammatory response</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">nephelometry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">plasma</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Larsson</subfield>
   <subfield code="D">Anders</subfield>
   <subfield code="u">Department of Medical Sciences, Clinical Chemistry, University Hospital, Uppsala, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hansson</subfield>
   <subfield code="D">Lars-Olof</subfield>
   <subfield code="u">Department of Medical Sciences, Clinical Chemistry, University Hospital, Uppsala, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Clinical Chemical Laboratory Medicine</subfield>
   <subfield code="d">Walter de Gruyter</subfield>
   <subfield code="g">42/12(2004-12-01), 1396-1400</subfield>
   <subfield code="x">1434-6621</subfield>
   <subfield code="q">42:12&lt;1396</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">42</subfield>
   <subfield code="o">cclm</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1515/CCLM.2004.260</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1515/CCLM.2004.260</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Larsson</subfield>
   <subfield code="D">Anders</subfield>
   <subfield code="u">Department of Medical Sciences, Clinical Chemistry, University Hospital, Uppsala, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hansson</subfield>
   <subfield code="D">Lars-Olof</subfield>
   <subfield code="u">Department of Medical Sciences, Clinical Chemistry, University Hospital, Uppsala, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Clinical Chemical Laboratory Medicine</subfield>
   <subfield code="d">Walter de Gruyter</subfield>
   <subfield code="g">42/12(2004-12-01), 1396-1400</subfield>
   <subfield code="x">1434-6621</subfield>
   <subfield code="q">42:12&lt;1396</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">42</subfield>
   <subfield code="o">cclm</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
