<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">378902040</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123520.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20040601xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1524/auto.52.6.280.33111</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.1524/auto.52.6.280.33111</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Geburtensimulator mit multimodaler Interaktion (Delivery Simulator with Multimodal Interaction)</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Tobias Obst, Rainer Burgkart, Eugen Ruckhäberle, Robert Riener]</subfield>
  </datafield>
  <datafield tag="246" ind1="1" ind2=" ">
   <subfield code="a">Delivery Simulator with Multimodal Interaction</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Der Beitrag bietet einen grundlegenden Überblick über das Potential der Techniken der Multimodalen Virtuellen Realität (MVR) in der medizinischen Ausbildung am Beispiel der Geburtshilfe. Die Studie zeigt, wie das Konzept der MVR von einer zeitunabhängigen Simulationsumgebung, z.B. die des Münchner Kniesimulators, auf eine zeitkritische Umgebung, ähnlich eines Flugsimulators, umgesetzt werden kann. Der Simulator verfügt über eine haptische, eine grafische und eine akustische Schnittstelle zum Anwender. Dabei ist sowohl ein biomechanisches Modell, das den Geburtsablauf repräsentiert, als auch ein physiologisches Modell von Mutter und Kind, worin ein Wehenschreiber (CTG) simuliert wird, hinterlegt. Der Anwender kann hierdurch eine komplikationslose Geburt, als auch problematische Geburtsabläufe beobachten und simulativ therapieren. Hierzu stehen ihm als Behandlungsmöglichkeiten die wichtigsten Medikamente als auch die Zangen- bzw. Vakuum-Extraktion zur Verfügung. In dieser praktischen Ausbildung wird der Lernende durch das MVR Feedback-System unterstützt, das ihm seine Fehler aufzeigt und ihm dadurch erlaubt, schneller zu lernen, ohne eine reale Patientin oder den Fetus zu gefährden. Durch dieses Konzept wird es erstmals möglich, gespeichertes haptisches Expertenwissen direkt an den Auszubildenden weiterzugeben.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">© 2004 Oldenbourg Wissenschaftsverlag GmbH</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Engineering: general</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Production engineering</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Electrical engineering</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Obst</subfield>
   <subfield code="D">Tobias</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Burgkart</subfield>
   <subfield code="D">Rainer</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ruckhäberle</subfield>
   <subfield code="D">Eugen</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Riener</subfield>
   <subfield code="D">Robert</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">at - Automatisierungstechnik/Methoden und Anwendungen der Steuerungs-, Regelungs- und Informationstechnik</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">52/6/2004(2004-06-01), 280-287</subfield>
   <subfield code="x">0178-2312</subfield>
   <subfield code="q">52:6/2004&lt;280</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">52</subfield>
   <subfield code="o">auto</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1524/auto.52.6.280.33111</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1524/auto.52.6.280.33111</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Obst</subfield>
   <subfield code="D">Tobias</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Burgkart</subfield>
   <subfield code="D">Rainer</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ruckhäberle</subfield>
   <subfield code="D">Eugen</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Riener</subfield>
   <subfield code="D">Robert</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">at - Automatisierungstechnik/Methoden und Anwendungen der Steuerungs-, Regelungs- und Informationstechnik</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">52/6/2004(2004-06-01), 280-287</subfield>
   <subfield code="x">0178-2312</subfield>
   <subfield code="q">52:6/2004&lt;280</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">52</subfield>
   <subfield code="o">auto</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
