Untersuchungen zu den Einflußgrößen auf die computergestützte Simulation von Kontakten in der dynamischen Okklusion anhand optisch digitalisierter Situationsmodelle

Verfasser / Beitragende:
Investigation of Influencing Variables on the Computer-Aided Simulation of Contacts in Dynamic Occlusion Based on Optically Digitized Plaster Casts / [Z Böröcz, D Dirksen, C Thomas, C Runte, F Bollmann, G von Bally]
Ort, Verlag, Jahr:
2004
Enthalten in:
Biomedizinische Technik/Biomedical Engineering, 49/5(2004-05-01), 111-116
Format:
Artikel (online)
ID: 378902474
LEADER caa a22 4500
001 378902474
003 CHVBK
005 20180305123521.0
007 cr unu---uuuuu
008 161128e20040501xx s 000 0 ger
024 7 0 |a 10.1515/BMT.2004.023  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1515/BMT.2004.023 
245 0 0 |a Untersuchungen zu den Einflußgrößen auf die computergestützte Simulation von Kontakten in der dynamischen Okklusion anhand optisch digitalisierter Situationsmodelle  |h [Elektronische Daten]  |c Investigation of Influencing Variables on the Computer-Aided Simulation of Contacts in Dynamic Occlusion Based on Optically Digitized Plaster Casts / [Z Böröcz, D Dirksen, C Thomas, C Runte, F Bollmann, G von Bally] 
520 3 |a In der Zahnheilkunde spielen mechanische Artikulatoren, mit denen sich Kaubewegungen anhand von Kiefermodellen nachvollziehen lassen, eine wichtige Rolle. Wesentliche Nachteile der üblicherweise genutzten teiladjustierbaren Artikulatoren bestehen darin, daß zum einen mit diesen Artikulatoren die Bewegungsbahnen der Kondylen nur näherungsweise nachvollzogen werden können und zum anderen damit keine Aussagen über den zugrundeliegenden zeitlichen Ablauf möglich sind. Beide Probleme sind im Prinzip lösbar, wenn anstelle eines mechanischen Artikulators eine digitale Simulation ("virtueller Artikulator") eingesetzt wird, die auf digitalisierten Kiefermodellen und am Patienten aufgezeichneten Bewegungen basiert. Es wird ein entsprechendes System vorgestellt, bei dem schädelgerecht ausgerichtete Situationsmodelle mit der Streifenprojektionstechnik dreidimensional vermessen und die Kondylenbewegungen durch elektronische Aufzeichnung dargestellt werden. Mit den entwickelten numerischen Algorithmen lassen sich dann für jede Bewegung die auftretenden Kontaktflächen sowie die Öffnungswinkelkurven bei dynamischer Okklusion berechnen. Am Beispiel eines Patientendatensatzes werden die Auswirkungen der bei der Digitalisierung von Situationsmodellen auftretenden Meßunsicherheiten auf die Berechnung der Öffnungswinkelkurven in Zusammenhang mit der Anatomie des Kauapparates diskutiert. In dentistry, mechanical articulators with which mandibular movements can be reproduced in dentals casts play a major role. Commonly used semiadjustable articulators, however, have major limitations: On the one hand, the movement of the mandible is not reproduced exactly, on the other, they do not provide time-related information on jaw movement. Both problems can be solved by replacing the mechanical articulator by a digital simulation ("virtual articulator”) based on digitized plaster casts and electronically recorded masticatory movements. We present a system for the 3D measurement of plaster casts in a skull-related, anatomical coordinate system using the fringe projection technique, and electronically recorded condylar movements. Using numerical algorithms, the contacts between upper and low jaw, and the angle of rotation of the temporomandibular joint can be computed for each movement in dynamic occlusion. Taking the data recorded from a patient as an example, the influence of the accuracy of the digitization of plaster casts on the computation of the rotation of the temporomandibular joint is discussed in relation to the anatomy of the masticatory apparatus. 
540 |a © Walter de Gruyter 
690 7 |a Virtueller Artikulator  |2 nationallicence 
690 7 |a 3-D-Koordinatenmeßtechnik  |2 nationallicence 
690 7 |a Öffnungswinkelkurven  |2 nationallicence 
690 7 |a Kontaktflächenuntersuchung  |2 nationallicence 
690 7 |a Virtual articulator  |2 nationallicence 
690 7 |a 3-D coordinate measurement  |2 nationallicence 
690 7 |a Apex angle  |2 nationallicence 
690 7 |a Contacts in dynamic occlusion  |2 nationallicence 
700 1 |a Böröcz  |D Z.  |u Universitätsklinikum Münster, Labor für Biophysik.  |4 aut 
700 1 |a Dirksen  |D D.  |u Universitätsklinikum Münster, Labor für Biophysik.  |4 aut 
700 1 |a Thomas  |D C.  |u Universitätsklinikum Münster, Labor für Biophysik.  |4 aut 
700 1 |a Runte  |D C.  |u Universitätsklinikum Münster, Poliklinik für Zahnärztliche Prothetik.  |4 aut 
700 1 |a Bollmann  |D F.  |u Universitätsklinikum Münster, Poliklinik für Zahnärztliche Prothetik.  |4 aut 
700 1 |a von Bally  |D G.  |u Universitätsklinikum Münster, Labor für Biophysik.  |4 aut 
773 0 |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/5(2004-05-01), 111-116  |x 0013-5585  |q 49:5<111  |1 2004  |2 49  |o bmte 
856 4 0 |u https://doi.org/10.1515/BMT.2004.023  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1515/BMT.2004.023  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Böröcz  |D Z.  |u Universitätsklinikum Münster, Labor für Biophysik  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Dirksen  |D D.  |u Universitätsklinikum Münster, Labor für Biophysik  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Thomas  |D C.  |u Universitätsklinikum Münster, Labor für Biophysik  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Runte  |D C.  |u Universitätsklinikum Münster, Poliklinik für Zahnärztliche Prothetik  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Bollmann  |D F.  |u Universitätsklinikum Münster, Poliklinik für Zahnärztliche Prothetik  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a von Bally  |D G.  |u Universitätsklinikum Münster, Labor für Biophysik  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/5(2004-05-01), 111-116  |x 0013-5585  |q 49:5<111  |1 2004  |2 49  |o bmte 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter