<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">378904442</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123526.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20040501xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1524/teme.71.5.290.33119</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.1524/teme.71.5.290.33119</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Horn</subfield>
   <subfield code="D">Michael</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Sensoren und Aktoren zur bedarfsgerechten Lüftung (Sensors and Actuators for a Demand-driven Air Ventilation)</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Michael Horn]</subfield>
  </datafield>
  <datafield tag="246" ind1="0" ind2=" ">
   <subfield code="a">Sensors and Actuators for a Demand-driven Air Ventilation</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Die Konzentration anthropogen erzeugter Stoffe erreicht bei der Anwesenheit von Personen in energiesparenden und damit zunehmend luftdichten Wohngebäuden sehr schnell unzulässige Werte. Lüftung führt zu Energieverlust und Immission und muss daher bedarfsgerecht durchgeführt sowie überwacht werden. Die zulässigen Grenzwerte für die Bestandteile &quot;guter” Luft sind zwar in Vorschriften definiert, aber wegen des Aufwandes nicht komplett kontrollierbar. Daher muss das Spektrum der kontrollierten Komponenten durch Szenarien mit hinreichender Wahrscheinlichkeit und die Definition von Leitsubstanzen eingeschränkt werden. Die für den Betrieb von Lüftungsgeräten notwendigen Messgrößen müssen im Smart Home ohne die im industriellen Bereich übliche regelmäßige Wartung preisgünstig, mit hinreichender Genauigkeit und hoher Langzeitstabilität gemessen werden. Dazu sind neue &quot;smart sensors” notwendig, deren Eigenschaften an die besonderen Anforderungen im privaten Lebensbereich angepasst werden können.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">© 2004 Oldenbourg Wissenschaftsverlag GmbH</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Engineering: general</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Instruments &amp; instrumentation engineering</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Materials science</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">tm - Technisches Messen/Sensoren, Geräte, Systeme</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">71/5/2004(2004-05-01), 290-297</subfield>
   <subfield code="x">0171-8096</subfield>
   <subfield code="q">71:5/2004&lt;290</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">71</subfield>
   <subfield code="o">teme</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1524/teme.71.5.290.33119</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1524/teme.71.5.290.33119</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Horn</subfield>
   <subfield code="D">Michael</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">tm - Technisches Messen/Sensoren, Geräte, Systeme</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">71/5/2004(2004-05-01), 290-297</subfield>
   <subfield code="x">0171-8096</subfield>
   <subfield code="q">71:5/2004&lt;290</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">71</subfield>
   <subfield code="o">teme</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
