<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">378906356</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123530.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20040301xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1524/teme.71.3.173.27990</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.1524/teme.71.3.173.27990</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Derbel</subfield>
   <subfield code="D">Faouzi</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Systemtechnisch orientierter Ansatz zur Simulation von Brandmeldersignalen (System Oriented Approach for Simulation of Fire Detector Signals)</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Faouzi Derbel]</subfield>
  </datafield>
  <datafield tag="246" ind1="0" ind2=" ">
   <subfield code="a">System Oriented Approach for Simulation of Fire Detector Signals</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Der Entwurf von Brandfrüherkennungsalgorithmen ist ein iterativer Prozess mit ständigen Verbesserungen von definierten Leistungseigenschaften, durch statistisch abgesicherte Werte über die Falschalarmraten bzw. mittleren Detektionszeiten beschrieben werden können. Um eine aussagekräftige Statistik zu erhalten, müssen Signale von Testbränden bzw. relevanten Störereignissen in großer Anzahl zur Verfügung stehen. Da die Durchführung dieser Testereignisse mit hohem Kostenaufwand verbunden ist, empfiehlt es sich, die Brandmeldersignale zu simulieren. In diesem Artikel wird eine neue Simulationsmethode präsentiert. Diese zeichnet sich durch einen systemtechnisch orientierten Ansatz sowie durch einen minimalen Rechenaufwand aus. Zuerst werden Parameter zur Beschreibung des Systemverhaltens unter Zuhilfenahme von Referenzsignalen aus Testereignissen gewonnen. Das Übertragungsverhalten bezüglich der Brandprodukte wird durch Gewichtsfunktionen und durch versuchsspezifische Einflussfaktoren beschrieben. Mit diesem Ansatz wurden Brandmeldersignale generiert, die den gemessenen ähnlich sind.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">© 2004 Oldenbourg Wissenschaftsverlag GmbH</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Engineering: general</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Instruments &amp; instrumentation engineering</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Materials science</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">tm - Technisches Messen/Sensoren, Geräte, Systeme</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">71/3/2004(2004-03-01), 173-183</subfield>
   <subfield code="x">0171-8096</subfield>
   <subfield code="q">71:3/2004&lt;173</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">71</subfield>
   <subfield code="o">teme</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1524/teme.71.3.173.27990</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1524/teme.71.3.173.27990</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Derbel</subfield>
   <subfield code="D">Faouzi</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">tm - Technisches Messen/Sensoren, Geräte, Systeme</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">71/3/2004(2004-03-01), 173-183</subfield>
   <subfield code="x">0171-8096</subfield>
   <subfield code="q">71:3/2004&lt;173</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">71</subfield>
   <subfield code="o">teme</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
