99mTc gel generators based on zirconium molybdate-99Mo: III: Influence of preparatory conditions of zirconium molybdate-99Mo gel on generator performance

Verfasser / Beitragende:
[P. Saraswathy, S. K. Sarkar, G. Arjun, S. K. Nandy, Natesan Ramamoorthy]
Ort, Verlag, Jahr:
2004
Enthalten in:
Radiochimica Acta/International journal for chemical aspects of nuclear science and technology, 92/4-6/2004(2004-04-01), 259-264
Format:
Artikel (online)
ID: 37890714X
LEADER caa a22 4500
001 37890714X
003 CHVBK
005 20180305123532.0
007 cr unu---uuuuu
008 161128e20040401xx s 000 0 eng
024 7 0 |a 10.1524/ract.92.4.259.35585  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1524/ract.92.4.259.35585 
245 0 0 |a 99mTc gel generators based on zirconium molybdate-99Mo: III: Influence of preparatory conditions of zirconium molybdate-99Mo gel on generator performance  |h [Elektronische Daten]  |c [P. Saraswathy, S. K. Sarkar, G. Arjun, S. K. Nandy, Natesan Ramamoorthy] 
520 3 |a The effect of subtle variations on zirconium molybdate-99Mo gel preparatory conditions, such as stoichiometry of reactants, pH of gel formation, conditioning of gel granules etc. , prior to elution were investigated primarily to arrive at the conditions resulting in high 99mTc release and minimal 99Mo breakthrough upon elution with normal saline. Zirconium molybdate- 99Mo gels were prepared by reacting solutions of Zr and Mo in mole ratios of 0.75-1.5. Both water and normal saline were used for gel disintegration, and the release of 99mTc and 99Mo from gel columns into eluates was compared. Sharper elution profile of 99mTc, but with significantly higher 99Mo breakthrough (5-8times), was obtained when water alone was used for disintegration and elution, in comparison to when saline was used. Gels exhibiting optimum characteristics were found to be formed at a pH of 4-5 by reacting [Zr]:[Mo] in the mole ratio of 1.25:1 and after drying, the product was dispersed into granules by disintegration with normal saline. 99mTc elution efficiency was found to be ∼75% and 99Mo breakthrough ∼0.05%. The elution profile was sharp when a 6g gel column coupled to a 2g acidic alumina column (to trap 99Mo) was eluted with 6-9ml normal saline. Generators containing upto 23GBq 99Mo were prepared, eluted extensively without changing the alumina column and found to provide pertechnetate of good quality, commensurate with hospital radiopharmacy requirements. 
540 |a © 2004 Oldenbourg Wissenschaftsverlag GmbH 
690 7 |a Laboratory techniques, experiments  |2 nationallicence 
690 7 |a Analytical chemistry  |2 nationallicence 
690 7 |a Inorganic chemistry  |2 nationallicence 
700 1 |a Saraswathy  |D P.  |4 aut 
700 1 |a Sarkar  |D S. K.  |4 aut 
700 1 |a Arjun  |D G.  |4 aut 
700 1 |a Nandy  |D S. K.  |4 aut 
700 1 |a Ramamoorthy  |D Natesan  |4 aut 
773 0 |t Radiochimica Acta/International journal for chemical aspects of nuclear science and technology  |d Oldenbourg Wissenschaftsverlag GmbH  |g 92/4-6/2004(2004-04-01), 259-264  |x 0033-8230  |q 92:4-6/2004<259  |1 2004  |2 92  |o ract 
856 4 0 |u https://doi.org/10.1524/ract.92.4.259.35585  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1524/ract.92.4.259.35585  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Saraswathy  |D P.  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Sarkar  |D S. K.  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Arjun  |D G.  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Nandy  |D S. K.  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ramamoorthy  |D Natesan  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Radiochimica Acta/International journal for chemical aspects of nuclear science and technology  |d Oldenbourg Wissenschaftsverlag GmbH  |g 92/4-6/2004(2004-04-01), 259-264  |x 0033-8230  |q 92:4-6/2004<259  |1 2004  |2 92  |o ract 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter