<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">37891202X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123544.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20040527xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.2202/1553-779X.1001</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.2202/1553-779X.1001</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Impact of Transmission Line Failures on the Cost/Risk-Based Spinning Reserve Allocation</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Lalit Goel, Z Song, P Wang]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">In deregulated power systems spinning reserve (SR) can be allocated to different ancillary service providers at different locations based on supplier bids and customer choices on reliability. This paper investigates the impact of transmission line failures using a cost/risk-based spinning reserve allocation method (CRSRAM). The proposed method provides minimum spinning reserve cost, while securing the reliability risk at a minimum in the presence of not only generating unit outages but also transmission line failures. The implementation of this technique in a SR market to determine the SR schedules is presented in the paper. The IEEE Reliability Test System (RTS) has been used to illustrate the applications of the proposed method.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">©2011 Walter de Gruyter GmbH &amp; Co. KG, Berlin/Boston</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">spinning reserve assessment</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">risk analysis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">deregulated systems</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Goel</subfield>
   <subfield code="D">Lalit</subfield>
   <subfield code="u">Nanyang Technological University</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Song</subfield>
   <subfield code="D">Z.</subfield>
   <subfield code="u">Nanyang Technological University</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Wang</subfield>
   <subfield code="D">P.</subfield>
   <subfield code="u">Nanyang Technological University</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">International Journal of Emerging Electric Power Systems</subfield>
   <subfield code="d">De Gruyter</subfield>
   <subfield code="g">1/1(2004-05-27)</subfield>
   <subfield code="q">1:1</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">1</subfield>
   <subfield code="o">ijeeps</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.2202/1553-779X.1001</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.2202/1553-779X.1001</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Goel</subfield>
   <subfield code="D">Lalit</subfield>
   <subfield code="u">Nanyang Technological University</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Song</subfield>
   <subfield code="D">Z.</subfield>
   <subfield code="u">Nanyang Technological University</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Wang</subfield>
   <subfield code="D">P.</subfield>
   <subfield code="u">Nanyang Technological University</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">International Journal of Emerging Electric Power Systems</subfield>
   <subfield code="d">De Gruyter</subfield>
   <subfield code="g">1/1(2004-05-27)</subfield>
   <subfield code="q">1:1</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">1</subfield>
   <subfield code="o">ijeeps</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
