<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">378919652</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123602.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20040901xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1524/teme.71.9.501.42748</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.1524/teme.71.9.501.42748</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Horn</subfield>
   <subfield code="D">Michael</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Anwendung der Impedanzspektrometrie zur Selbstüberwachung amperometrischer Gassensoren (Use of Impedance Spectrometry for Self-Monitoring of Amperometric Gas Sensors)</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Michael Horn]</subfield>
  </datafield>
  <datafield tag="246" ind1="0" ind2=" ">
   <subfield code="a">Use of Impedance Spectrometry for Self-Monitoring of Amperometric Gas Sensors</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Die Empfindlichkeit amperometrischer Gassensoren ist proportional zur Größe der elektrochemisch aktiven Fläche. Die Größe dieser Fläche verringert sich durch Ablagerungen und Verschmutzung des Katalysators und sollte deshalb während des Betriebes automatisch überwacht werden. Da die Doppelschichtkapazität und der Durchtrittsleitwert ebenfalls proportional zur Elektrodenfläche sind, können diese durch impedanzspektrometrische Messungen bestimmt und zur Selbstüberwachung der Sensoren herangezogen werden. Die Bestimmung der Größe der Doppelschichtkapazität erfolgt durch modellgestützte Auswertung der Impedanzspektren der gesamten Messanordnung, deren Ersatzschaltbild durch einen Satz von insgesamt neun Modellparametern gekennzeichnet ist gekennzeichnet ist. Die Analyse dieser neun Parameter zeigt, dass davon nur zwei exemplarspezifisch sind und während des Betriebes bestimmt werden müssen; die anderen sind typspezifisch bzw. im gewählten Frequenzbereich nicht relevant.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">© 2004 Oldenbourg Wissenschaftsverlag GmbH</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Engineering: general</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Instruments &amp; instrumentation engineering</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Materials science</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">tm - Technisches Messen/Sensoren, Geräte, Systeme</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">71/9/2004(2004-09-01), 501-508</subfield>
   <subfield code="x">0171-8096</subfield>
   <subfield code="q">71:9/2004&lt;501</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">71</subfield>
   <subfield code="o">teme</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1524/teme.71.9.501.42748</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1524/teme.71.9.501.42748</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Horn</subfield>
   <subfield code="D">Michael</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">tm - Technisches Messen/Sensoren, Geräte, Systeme</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">71/9/2004(2004-09-01), 501-508</subfield>
   <subfield code="x">0171-8096</subfield>
   <subfield code="q">71:9/2004&lt;501</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">71</subfield>
   <subfield code="o">teme</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
