Entwicklung einer universellen Schnittstellen umgebung zur Übertragung medizinischer Bilddaten mit magnetooptischen Medien
Gespeichert in:
Verfasser / Beitragende:
Development of a Universal Interface for the Exchange of Medical Image Data Using Magneto-optical Media / [J Kaminsky, Th Rodt, A Newe, F Donnerstag, M Zumkeller]
Ort, Verlag, Jahr:
2004
Enthalten in:
Biomedizinische Technik/Biomedical Engineering, 49/1-2(2004-02-01), 6-10
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 378924516 | ||
| 003 | CHVBK | ||
| 005 | 20180305123613.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 161128e20040201xx s 000 0 ger | ||
| 024 | 7 | 0 | |a 10.1515/BMT.2004.002 |2 doi |
| 035 | |a (NATIONALLICENCE)gruyter-10.1515/BMT.2004.002 | ||
| 245 | 0 | 0 | |a Entwicklung einer universellen Schnittstellen umgebung zur Übertragung medizinischer Bilddaten mit magnetooptischen Medien |h [Elektronische Daten] |c Development of a Universal Interface for the Exchange of Medical Image Data Using Magneto-optical Media / [J Kaminsky, Th Rodt, A Newe, F Donnerstag, M Zumkeller] |
| 520 | 3 | |a Digitale medizinische Bilddaten stellen die Grundlage für moderne Verfahren in der radiologischen Diagnostik und für präoperative Planungen dar. Trotz der Etablierung des DICOM-3.0-Standards zur Kommunikation medizinischer Bilddaten ist die Verwendung bestehender Bildinformationen oft durch eine Inkompatibilität der Datenformate zwischen Geräte-Generationen sowie durch die Verwendung Hersteller-proprietärer Formate limitiert. Eine Schnittstellenumgebung auf der Basis magnetooptischer Medien wurde entwickelt, um medizinische Bilddaten unabhängig von Geräte-Generation und spezifischen Formaten zu gewinnen und darzustellen. Hierfür mußten speziell adaptierte Routinen zur Gewinnung der Daten entwickelt werden. Eine modulare Programmstruktur wurde verwendet, um weitere Routinen und Übertragungsmedien flexibel implementieren zu können. Mehr als 20 000 CT- und MRT-Bilder inklusive der Header-Informationen, die mit verschiedenen General- Electric- und Siemens-Geräten gewonnen wurden, konnten erfolgreich von magnetooptischen Medien extrahiert werden. Die Bilddaten wurden zur Verlaufkontrolle und zur präoperativen Planung verwendet und in einen PAC-Server integriert. Der Datentransfer mit der entwickelten Schnittstellenumgebung ist zuverlässig und benutzerfreundlich. Die Implementierung weiterer Herstellter-proprietärer Formate ist Bestandteil einer gegenwärtigen Weiterentwicklung. Die entwickelte Schnittstellenumgebung erlaubt die zuverlässige Bereitstellung digitaler Bilddaten für die medizinische Diagnostik und die präoperative Planung, unabhängig von Geräte-Generationen und Hersteller-proprietären Formaten. Digital images generated by medical imaging form the basis for radiological diagnosis and surgical planning. Despite the advent of the DICOM 3.0 standard for medical image communication, widespread application of the existing information is often limited by incompatibility of the data formatting used by different equipment generations, and the manufacturer-specific standards employed. An exchange interface based on magneto optical discs has been developed to retrieve and present medical image data regardless of the technological hardware and the specific formats used. Specially adapted routines to retrieve the data first had to be developed. A modular program structure was used to allow flexibility in the implementation of further routines and other exchange media. Over 20,000 CT and MRI images including header information obtained from different General Electric and Siemens scanners were extracted successfully from MO discs. The image data were used for follow up and surgical planning and were transferred to a PAC-server. The interface proved reliable and easy to use. Support for further proprietary formats is currently being developed. The present exchange interface permits reliable retrieval of digital images for diagnostic and surgical planning purposes, regardless of the hardware generation and manufacturer-specific formats. | |
| 540 | |a © Walter de Gruyter | ||
| 690 | 7 | |a Digitale Bilder |2 nationallicence | |
| 690 | 7 | |a magnetooptische Medien |2 nationallicence | |
| 690 | 7 | |a DICOM |2 nationallicence | |
| 690 | 7 | |a PACS |2 nationallicence | |
| 690 | 7 | |a Schnittstelle |2 nationallicence | |
| 690 | 7 | |a Digital images |2 nationallicence | |
| 690 | 7 | |a Magneto-optical disc |2 nationallicence | |
| 690 | 7 | |a DICOM |2 nationallicence | |
| 690 | 7 | |a PACS |2 nationallicence | |
| 690 | 7 | |a Interface |2 nationallicence | |
| 700 | 1 | |a Kaminsky |D J. |u Kliniken für Neurochirurgie, Medizinische Hochschule Hannover. |4 aut | |
| 700 | 1 | |a Rodt |D Th |u Kliniken für Neurochirurgie; Kliniken für Neuroradiologie, Medizinische Hochschule Hannover. |4 aut | |
| 700 | 1 | |a Newe |D A. |u Kliniken für Neurochirurgie, Medizinische Hochschule Hannover. |4 aut | |
| 700 | 1 | |a Donnerstag |D F. |u Kliniken für Neuroradiologie, Medizinische Hochschule Hannover. |4 aut | |
| 700 | 1 | |a Zumkeller |D M. |u Kliniken für Neurochirurgie, Medizinische Hochschule Hannover. |4 aut | |
| 773 | 0 | |t Biomedizinische Technik/Biomedical Engineering |d Walter de Gruyter |g 49/1-2(2004-02-01), 6-10 |x 0013-5585 |q 49:1-2<6 |1 2004 |2 49 |o bmte | |
| 856 | 4 | 0 | |u https://doi.org/10.1515/BMT.2004.002 |q text/html |z Onlinezugriff via DOI |
| 908 | |D 1 |a research article |2 jats | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1515/BMT.2004.002 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Kaminsky |D J. |u Kliniken für Neurochirurgie, Medizinische Hochschule Hannover |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Rodt |D Th |u Kliniken für Neurochirurgie; Kliniken für Neuroradiologie, Medizinische Hochschule Hannover |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Newe |D A. |u Kliniken für Neurochirurgie, Medizinische Hochschule Hannover |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Donnerstag |D F. |u Kliniken für Neuroradiologie, Medizinische Hochschule Hannover |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Zumkeller |D M. |u Kliniken für Neurochirurgie, Medizinische Hochschule Hannover |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Biomedizinische Technik/Biomedical Engineering |d Walter de Gruyter |g 49/1-2(2004-02-01), 6-10 |x 0013-5585 |q 49:1-2<6 |1 2004 |2 49 |o bmte | ||
| 900 | 7 | |b CC0 |u http://creativecommons.org/publicdomain/zero/1.0 |2 nationallicence | |