<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">378926276</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123618.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20040617xx      s     000 0 mul  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1515/LabMed.2004.028</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.1515/LabMed.2004.028</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Vogeser</subfield>
   <subfield code="D">M.</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Anwendung der HPLC-Tandem-Massenspektrometrie in der klinischen Chemie</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">The use of HPLC-tandem mass spectrometry in clinical chemistry / [M. Vogeser]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The technology of liquid chromatography-tandem mass spectrometry opens the perspective of a more widespread use of highly specific mass spectrometric assays in a routine clinical laboratory setting as compared to gas chromatography-mass spectrometry. After the first years of routine application of liquid chromatography-tandem mass spectrometry in a growing number of laboratories, it has become evident that this technique will become a substantial part of the methodological spectrum of laboratory medicine. This is due to the very wide range of potential analytes to be measured with no limitation by molecular mass, the straightforward sample preparation not requiring chemical derivatization and due to the rugged instrumentation with limited maintenance requirements. This review gives a survey of the technical principles of liquid chromatography-tandem mass spectrometry, describes the basics of method development and typical routine applications, discusses strengths and limitations of the technique, and highlights the perspectives for future developments of the technology.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Copyright (c) 2004 by Walter de Gruyter GmbH &amp; Co. KG</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Medical equipment &amp; techniques</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Medical diagnosis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Diseases &amp; disorders</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">LaboratoriumsMedizin</subfield>
   <subfield code="d">Walter de Gruyter</subfield>
   <subfield code="g">28/3(2004-06-17), 195-204</subfield>
   <subfield code="x">0342-3026</subfield>
   <subfield code="q">28:3&lt;195</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">28</subfield>
   <subfield code="o">labm</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1515/LabMed.2004.028</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1515/LabMed.2004.028</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Vogeser</subfield>
   <subfield code="D">M.</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">LaboratoriumsMedizin</subfield>
   <subfield code="d">Walter de Gruyter</subfield>
   <subfield code="g">28/3(2004-06-17), 195-204</subfield>
   <subfield code="x">0342-3026</subfield>
   <subfield code="q">28:3&lt;195</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">28</subfield>
   <subfield code="o">labm</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="986" ind1=" " ind2=" ">
   <subfield code="a">SWISSBIB</subfield>
   <subfield code="b">378926276</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
