Anwendung eines Bandscheibenersatzimplantats aus einer neuartigen porösen TiO2/Glas-Keramik - Teil 1: Einsatz in der Schafs-Halswirbelsäule und radiologische Verlaufsuntersuchungen

Verfasser / Beitragende:
Application of a Stand-Alone Interbody Fusion Cage Based on a Novel Porous TiO2/glass Composite - Part 1: Implantation in the Sheep Cervical Spine and Radiological Evaluation / [M. C Korinth, T Hero, A. H Mahnken, C Ragoß, K Scherer]
Ort, Verlag, Jahr:
2004
Enthalten in:
Biomedizinische Technik/Biomedical Engineering, 49/12(2004-12-01), 356-363
Format:
Artikel (online)
ID: 378926349
LEADER caa a22 4500
001 378926349
003 CHVBK
005 20180305123618.0
007 cr unu---uuuuu
008 161128e20041201xx s 000 0 ger
024 7 0 |a 10.1515/BMT.2004.066  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1515/BMT.2004.066 
245 0 0 |a Anwendung eines Bandscheibenersatzimplantats aus einer neuartigen porösen TiO2/Glas-Keramik - Teil 1: Einsatz in der Schafs-Halswirbelsäule und radiologische Verlaufsuntersuchungen  |h [Elektronische Daten]  |c Application of a Stand-Alone Interbody Fusion Cage Based on a Novel Porous TiO2/glass Composite - Part 1: Implantation in the Sheep Cervical Spine and Radiological Evaluation / [M. C Korinth, T Hero, A. H Mahnken, C Ragoß, K Scherer] 
520 3 |a Zur Beurteilung des radiologischen, biomechanischen und histologischen Einwachsverhaltens neuer Materialien, Implantate und Cages für die zervikale interkorporelle Fusion, bieten sich Tiermodelle und hier insbesondere das Schafs-Halswirbelsäulenmodell an. In biomechanischen In-vitro-Versuchen an humanen Kadaver-Halswirbelsäulen wurden erste Erfahrungen hinsichtlich Primärstabilität eines Cage aus einer neuartigen, porösen TiO2/Glas-Keramik (Ecopore) im Vergleich zu Polymethylmethacrylat (PMMA) gewonnen. Zur entsprechenden In-vivo-Beurteilung fusionierten wir 10 Schafs-Halswirbelsäulen in den Höhen C2/3 und C4/5 jeweils mit PMMA und einem Ecopore-Keramik-Cage und führten nativradiologische, sowie computertomographische Verlaufsuntersuchungen direkt post-operativ und alle 4 Wochen in den folgenden 2 bzw. 4 Monaten durch. Neben der Etablierung des Tiermodells, wurden die radiologischen Veränderungen im Verlauf und die Fusion der operierten Segmente analysiert. Darüberhinaus wurden Messungen der entsprechenden Bandscheibenfachhöhen (DSH) und Intervertebralwinkel (IVA) durchgeführt und verglichen. Nach Einbringen der Implantate in die Bandscheibenfächer nahm zunächst in beiden Gruppen die mittlere Bandscheibenfachhöhe und der Intervertebralwinkel zu (34,8%; 53,9%). In den folgenden Monaten verringerte sich die Bandscheibenfachhöhe nicht signifikant, deutlicher nach Ecopore-Fusion als nach PMMA-Interposition bis auf Werte unterhalb der Ausgangswerte. Ebenso nahm der Intervertebralwinkel im postoperativen Verlauf, deutlicher in der Ecopore-Gruppe als in der PMMA-Gruppe, ab (p < 0,05). Diese Veränderungen im Sinne einer Einsinterung der Implantate, konnte in den radiologischen Verlaufskontrollen morphologisch bestätigt werden. Die radiologisch beurteilbare Fusion, d.h. solide knöcherne Überbauung des operierten Segments, war nach Implantation eines Ecopore-Cage ausgeprägter (83%) als nach PMMA-Interposition (50%) (nicht statistisch signifikant). In diesem ersten Teil unserer In-vivo-Untersuchungen zu dem Einsatz des neuartigen Cage-Materials wurde die Anwendung im Spondylodesemodell der Schafs-Halswirbelsäule aufgezeigt. Es zeigten sich radiologische Unterschiede, in Bezug auf die ausgeprägtere Einsinterung des Ecopore-Cage und die deutlichere, nachweisbare Fusion des mit dem neuen Material operierten Segments. In dem ersten Teil dieser Studie wurden die radiologischen Veränderungen der fusionierten Segmente über mehrere Monate dargestellt und morphologisch analysiert, bevor die biomechanischen Analysen und Vergleiche in einem weiteren Teil präsentiert werden sollen. Animals are becoming more and more common as in vitro and in vivo models for the human spine. Especially the sheep cervical spine is stated to be of good comparability and usefulness in the evaluation of in vivo radiological, biomechanical and histological behaviour of new bone replacement materials, implants and cages for cervical spine interbody fusion. In preceding biomechanical in vitro examination human cervical spine specimens were tested after fusion with either a cubical stand-alone interbody fusion cage manufactured from a new porous TiO2/glass composite (Ecopore) or polymethyl-methacrylate (PMMA) after discectomy. First experience with the use of the new material and its influence on the primary stability after in vitro application were gained. After fusion of 10 sheep cervical spines in the levels C2/3 and C4/5 in each case with PMMA and with an Ecopore-cage, radiologic as well as computertomographic examinations were performed postoperatively and every 4 weeks during the following 2 and 4 months, respectively. Apart from establishing our animal model, we analysed the radiological changes and the degree of bony fusion of the operated segments during the course. In addition we performed measurements of the corresponding disc space heights (DSH) and intervertebral angles (IVA) for comparison among each other, during the course and with the initial values. Immediately after placement of both implants in the disc spaces the mean DSH and IVA increased (34.8% and 53.9%, respectively). During the following months DSH decreased to a greater extent in the Ecopore-segments than in the PMMA-segments, even to a value below the initial value (p > 0,05). Similarly, the IVA decreased in both groups in the postoperative time lapse, but more distinct in the Ecopore-segments (p < 0,05). These changes in terms of a subsidence of the implants, were confirmed morphologically in the radiological examination in the course. The radiologically evaluated fusion, i.e. bony bridging of the operated segments, was more pronounced after implantation of an Ecopore-cage (83%), than after PMMA interposition (50%), but did not gain statistical significance. In this first in vivo examination of our new porous ceramic bone replacement material we showed its application in the spondylodesis model of the sheep cervical spine. Distinct radiological changes regarding evident subsidence and detectable fusion of the segments, operated on with the new biomaterial, were seen. We demonstrated the radiological changes of the fused segments during several months and analysed them morphologically, before the biomechanical evaluation will be presented in a subsequent publication. 
540 |a © Walter de Gruyter 
690 7 |a Tiermodell  |2 nationallicence 
690 7 |a Schaf  |2 nationallicence 
690 7 |a Halswirbelsäule  |2 nationallicence 
690 7 |a poröse TiO2/Glas-Keramik  |2 nationallicence 
690 7 |a Polymethylmethacrylat  |2 nationallicence 
690 7 |a radiologiche Bildgebung  |2 nationallicence 
690 7 |a Animal model  |2 nationallicence 
690 7 |a sheep  |2 nationallicence 
690 7 |a cervical spine  |2 nationallicence 
690 7 |a porous TiO2/glass composite  |2 nationallicence 
690 7 |a bone cement  |2 nationallicence 
690 7 |a radiological evaluation  |2 nationallicence 
700 1 |a Korinth  |D M. C.  |u Neurochirurgische Universitätsklinik, Dir.: Prof. Dr. med. J. M. Gilsbach.  |4 aut 
700 1 |a Hero  |D T.  |u Neurochirurgische Universitätsklinik, Dir.: Prof. Dr. med. J. M. Gilsbach.  |4 aut 
700 1 |a Mahnken  |D A. H.  |u Radiologische Universitätsklinik, Dir.: Prof. Dr. med. R. W. Günther.  |4 aut 
700 1 |a Ragoß  |D C.  |u Institut für Keramische Komponenten im Maschinenbau, Dir.: Prof. Dr.-Ing. H. R. Maier.  |4 aut 
700 1 |a Scherer  |D K.  |u Institut für Versuchstierkunde RWTH Aachen, Dir.: Prof. Dr. vet. W. Küpper, RWTH Aachen.  |4 aut 
773 0 |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/12(2004-12-01), 356-363  |x 0013-5585  |q 49:12<356  |1 2004  |2 49  |o bmte 
856 4 0 |u https://doi.org/10.1515/BMT.2004.066  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1515/BMT.2004.066  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Korinth  |D M. C.  |u Neurochirurgische Universitätsklinik, Dir.: Prof. Dr. med. J. M. Gilsbach  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Hero  |D T.  |u Neurochirurgische Universitätsklinik, Dir.: Prof. Dr. med. J. M. Gilsbach  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Mahnken  |D A. H.  |u Radiologische Universitätsklinik, Dir.: Prof. Dr. med. R. W. Günther  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ragoß  |D C.  |u Institut für Keramische Komponenten im Maschinenbau, Dir.: Prof. Dr.-Ing. H. R. Maier  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Scherer  |D K.  |u Institut für Versuchstierkunde RWTH Aachen, Dir.: Prof. Dr. vet. W. Küpper, RWTH Aachen  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/12(2004-12-01), 356-363  |x 0013-5585  |q 49:12<356  |1 2004  |2 49  |o bmte 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
986 |a SWISSBIB  |b 378926349 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter