<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">378933930</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123636.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20040401xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1524/teme.71.4.259.30457</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.1524/teme.71.4.259.30457</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Neuartige Regelung eines Coriolis-Massedurchflussmessers (A Novel Control Algorithm for Coriolis Mass Flowmeters)</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Thorsten Schröder, Kourosh Kolahi, Helmut Röck]</subfield>
  </datafield>
  <datafield tag="246" ind1="1" ind2=" ">
   <subfield code="a">A Novel Control Algorithm for Coriolis Mass Flowmeters</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Coriolis-Massedurchflussmesser (CMD) zeichnen sich durch eine hohe Messgenauigkeit bei gleichzeitig kleiner Querempfindlichkeit gegenüber den Fluideigenschaften aus. Allerdings zeigt sich unter schwierigen Prozessbedingungen, insbesondere bei CMD mit einem einzigen geraden Messrohr, das Problem einer Änderung von Nullpunkt und Empfindlichkeit. In dieser Arbeit wird ein modellbasierter Ansatz zur On-line-Bestimmung dieser Kenngrößen des CMD vorgestellt. Er basiert auf der Kompensation sowohl der Corioliskräfte als auch der internen Kopplungen des CMD. Zur Realisierung des Kompensationsverfahrens wird eine neuartige Regelung, bestehend aus zwei kaskadierten Reglern, vorgestellt. Der äußere Regelkreis basiert auf einem Zeigerverfahren und einem optimalen Zustandsregler (LQ-Regler) für die Ausgangssignale des CMD. Der innere Kreis regelt die Phasendifferenz zwischen Ein- und Ausgangssignal des 1. Modes des Messrohres, indem die Antriebsfrequenz verstellt wird. Er gewährleistet den Betrieb des CMD in der Eigenfrequenz des 1. Modes.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">© 2004 Oldenbourg Wissenschaftsverlag GmbH</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Engineering: general</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Instruments &amp; instrumentation engineering</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Materials science</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Schröder</subfield>
   <subfield code="D">Thorsten</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kolahi</subfield>
   <subfield code="D">Kourosh</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Röck</subfield>
   <subfield code="D">Helmut</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">tm - Technisches Messen/Sensoren, Geräte, Systeme</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">71/4/2004(2004-04-01), 259-268</subfield>
   <subfield code="x">0171-8096</subfield>
   <subfield code="q">71:4/2004&lt;259</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">71</subfield>
   <subfield code="o">teme</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1524/teme.71.4.259.30457</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1524/teme.71.4.259.30457</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Schröder</subfield>
   <subfield code="D">Thorsten</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kolahi</subfield>
   <subfield code="D">Kourosh</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Röck</subfield>
   <subfield code="D">Helmut</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">tm - Technisches Messen/Sensoren, Geräte, Systeme</subfield>
   <subfield code="d">Oldenbourg Wissenschaftsverlag GmbH</subfield>
   <subfield code="g">71/4/2004(2004-04-01), 259-268</subfield>
   <subfield code="x">0171-8096</subfield>
   <subfield code="q">71:4/2004&lt;259</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">71</subfield>
   <subfield code="o">teme</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
