<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">378935216</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123639.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20041219xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.2202/1553-779X.1013</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.2202/1553-779X.1013</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Tag Eldin</subfield>
   <subfield code="D">El Sayed M.</subfield>
   <subfield code="u">Cairo University</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="2">
   <subfield code="a">A Novel Approach for Classifying Transient Phenomena in Power Transformers</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[El Sayed M. Tag Eldin]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The role of a power transformer protective relay is to rapidly operate the tripping during internal faults and block the tripping during magnetizing inrush. This paper presents a new approach for classifying transient phenomena in power transformer, which may be implemented in digital relaying for transformer differential protection. Discrimination between internal faults, external faults with current transformer saturation and magnetizing inrush currents is achieved by combining wavelet transforms and fuzzy logic. The wavelet transform is applied for the analysis of the power transformer transient phenomena because of its ability to extract information from the transient signals in both time and frequency domain. Fuzzy logic is used because of the uncertainty in the differential current signals and relay settings. MATLAB power system toolbox is used to generate current signals at both sides of a power transformer in a typical system with various conditions. The simulation results obtained show that the new algorithm provides a high operating sensitivity for internal faults and remains stable for external faults and inrush currents.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">©2011 Walter de Gruyter GmbH &amp; Co. KG, Berlin/Boston</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Differential protection</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Fuzzy logic</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Power transformer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Relay</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Wavelet transforms</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">International Journal of Emerging Electric Power Systems</subfield>
   <subfield code="d">De Gruyter</subfield>
   <subfield code="g">1/2(2004-12-19)</subfield>
   <subfield code="q">1:2</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">1</subfield>
   <subfield code="o">ijeeps</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.2202/1553-779X.1013</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.2202/1553-779X.1013</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Tag Eldin</subfield>
   <subfield code="D">El Sayed M.</subfield>
   <subfield code="u">Cairo University</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">International Journal of Emerging Electric Power Systems</subfield>
   <subfield code="d">De Gruyter</subfield>
   <subfield code="g">1/2(2004-12-19)</subfield>
   <subfield code="q">1:2</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">1</subfield>
   <subfield code="o">ijeeps</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
