<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">378938290</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180305123646.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161128e20041201xx      s     000 0 mul  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1515/LabMed.2004.070</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)gruyter-10.1515/LabMed.2004.070</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Validierung des MELISA®-Tests zum Nachweis einer Metallüberempfindlichkeit. Validity of MELISA® for metal sensitivity testing</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Elizabeth Valentine-Thon, Hans-Walter Schiwara]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung In dieser Studie wurden Reproduzierbarkeit, Sensitivität, Spezifität und Zuverlässigkeit des MELISA®-Tests zum Nachweis von Metallüberempfindlichkeiten bei Patienten mit klinischen Symptomen einer Typ IV-Allergie gegen Metalle untersucht. Von 250 Patienten wurde Blut im MELISA® gegen bis zu 20 Metalle in 2 bis 3 verschiedenen Konzentrationen getestet. Häufigkeit und Verteilung positiver Testergebnisse, Sensitivität und Spezifität des Tests bei Patienten mit und ohne gesicherte oder vermutete Nickelallergie sowie die Bedeutung der Lymphozytenzahl und der Konzentration von anorganischem Quecksilber im Testsystem wurden untersucht. Darüberhinaus wurden für die Reproduzierbarkeitstestung 196 MELISA®-Tests im Doppelansatz durchgeführt und die Intra- und Interassay-Variationen bei Patienten mit positivem Epikutan-Test für die entsprechenden Metalle bestimmt. Von den 250 Patienten reagierten 26% gegen kein Metall, 36% gegen 1, 15% gegen 2, 12% gegen 3, 6% gegen 4 und 5% gegen ≥5 Metalle positiv im MELISA®-Test. Die positiven Ergebnisse gegen die einzelnen Metalle wiesen folgende Häufigkeiten auf: Nickel (73%), Titan (42%), Cadmium (18%), Gold (17%), Palladium (13%), Blei (11%), Beryllium (9%), anorganisches Quecksilber (8%), Zinn (8%) und Phenylquecksilber (6%). Alle Patienten, bei denen eine Nickelallergie vermutet oder gesichert wurde (n=15), reagierten im MELISA®-Test positiv, während Patienten ohne Verdacht auf eine Nickelallergie entweder negativ (n=6) oder sehr schwach positiv (n=4) reagierten. Die Reaktivität des MELISA®-Tests hängt von der Lymphozytenkonzentration ab: je höher die Lymphozytenkonzentration im Test, desto stärker die Reaktion. Eine Konzentration von &gt;0,5μg/ml anorganischem Quecksilber verursacht bei den meisten Patienten eine nicht antigen-spezifische (mitogene) Reaktion. Die Reproduzierbarkeit betrug 94% bei einem Stimulationsindex von ≥3 und 99% bei einem Index von ≥5 als Cut-off. Während die absoluten Intra- und Interassay-Stimulations-Indices variieren können, sind die qualitativen Ergebnisse in hohem Grade reproduzierbar. Der MELISA®-Test ist also reproduzierbar, sensitiv, spezifisch und zuverlässig für den Nachweis einer Metall-unverträglichkeit bei gegen Metalle sensibilisierten Patienten.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">©2004 by Walter de Gruyter Berlin New York</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Medical equipment &amp; techniques</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Medical diagnosis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Diseases &amp; disorders</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Lymphozyten-Transformations-Test</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">MELISA®-Test</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Metallunverträglichkeit</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Nickel</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Queck-silber</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">lymphocyte transformation test</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">MELISA®-Test</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">mercury</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">metal allergy</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">nickel</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Valentine-Thon</subfield>
   <subfield code="D">Elizabeth</subfield>
   <subfield code="u">MELISA (LTT) Center, Gemeinschaftspraxis für Laboratoriumsmedizin Dr. M. Sandkamp, B. Köster, Dr. R. Hiller, Bremen, Ge Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Schiwara</subfield>
   <subfield code="D">Hans-Walter</subfield>
   <subfield code="u">im Ruhestand, ehemals Labor Dr. Schiwara &amp; Partner, Bremen, Ge Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">LaboratoriumsMedizin</subfield>
   <subfield code="d">Walter de Gruyter</subfield>
   <subfield code="g">28/6(2004-12-01), 525-533</subfield>
   <subfield code="x">0342-3026</subfield>
   <subfield code="q">28:6&lt;525</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">28</subfield>
   <subfield code="o">labm</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1515/LabMed.2004.070</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1515/LabMed.2004.070</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Valentine-Thon</subfield>
   <subfield code="D">Elizabeth</subfield>
   <subfield code="u">MELISA (LTT) Center, Gemeinschaftspraxis für Laboratoriumsmedizin Dr. M. Sandkamp, B. Köster, Dr. R. Hiller, Bremen, Ge Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Schiwara</subfield>
   <subfield code="D">Hans-Walter</subfield>
   <subfield code="u">im Ruhestand, ehemals Labor Dr. Schiwara &amp; Partner, Bremen, Ge Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">LaboratoriumsMedizin</subfield>
   <subfield code="d">Walter de Gruyter</subfield>
   <subfield code="g">28/6(2004-12-01), 525-533</subfield>
   <subfield code="x">0342-3026</subfield>
   <subfield code="q">28:6&lt;525</subfield>
   <subfield code="1">2004</subfield>
   <subfield code="2">28</subfield>
   <subfield code="o">labm</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-gruyter</subfield>
  </datafield>
 </record>
</collection>
