Die Anwendbarkeit der digitalen Kolposkopie für telematische Fragestellungen

Verfasser / Beitragende:
The Suitability of Digital Colposcopy for Telematic Applications / [D Schädel, A Coumbos, St Ey, R.-G Willrodt, W Kühn, H Albrecht]
Ort, Verlag, Jahr:
2004
Enthalten in:
Biomedizinische Technik/Biomedical Engineering, 49/6(2004-06-01), 157-162
Format:
Artikel (online)
ID: 378939971
LEADER caa a22 4500
001 378939971
003 CHVBK
005 20180305123649.0
007 cr unu---uuuuu
008 161128e20040601xx s 000 0 ger
024 7 0 |a 10.1515/BMT.2004.030  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1515/BMT.2004.030 
245 0 4 |a Die Anwendbarkeit der digitalen Kolposkopie für telematische Fragestellungen  |h [Elektronische Daten]  |c The Suitability of Digital Colposcopy for Telematic Applications / [D Schädel, A Coumbos, St Ey, R.-G Willrodt, W Kühn, H Albrecht] 
520 3 |a Das Zervixkarzinom zählt zu den häufigsten Krebserkrankungen der Frau, weshalb den Untersuchungen zur Krebsfrüherkennung eine besondere Bedeutung zukommt. Die Kolposkopie ist eine technisch einfache Methode, um frühzeitig auffällige Epithele zu erkennen. Nachteile der Kolposkopie bestehen in der geringen Spezifität und der hohen Inter-und Intraobserver-Variabilität. Innerhalb einer klinischen Pilotstudie erfolgte die Evaluation eines digitalen Kolposkopiesystems, bestehend aus einem herkömmlichen binokularen Kolposkop, gekoppelt mit einer CCD-Kamera und einem PC. Ziel der Studie war es, die Reproduzierbarkeit bei der Befundung von zervikalen Läsionen zu untersuchen und die Anwendbarkeit der digitalen Kolposkopie für telematische Fragestellungen zu prüfen. Insgesamt wurden 315 Patientinnen untersucht und statistisch ausgewertet. Die Patientinnen wurden zunächst einer herkömmlichen kolposkopischen Untersuchung unterzogen und diagnostiziert. Während dieser Untersuchung wurden digitale Bilder gespeichert, auf deren Basis ein zweiter in der Kolposkopie erfahrener Arzt eine Re-Evaluation der Befunde vornahm. Primär- und Sekundärbefunde jeder Patientin wurden in Anlehnung an die Rom-Klassifikation in 4 Befundklassen eingeteilt und verglichen. Zwischen Primär- und Sekundäruntersuchung bestand in 69 % der Fälle Übereinstimmung in der Befundeinstufung (κ = 0,60 ± 0,03). Es wurde kein statistisch signifikanter Bias zur Über- oder Unterbewertung festgestellt. Der Anteil der nichtauswertbaren Kolposkopien betrug 9,2 %. Damit ist die digitale Kolposkopie geeignet, Befunde am PC zu reproduzieren, vorausgesetzt, es liegen eine hinreichende Bildqualität und ein geeignetes Klassifikationsmodell zur Befundeinstufung vor. Durch die digitale Kolposkopie ergaben sich deutliche Vorteile im Hinblick auf die Verlaufskontrolle (Follow-up), die interne Qualitätskontrolle der Diagnose sowie die Aus- und Weiterbildung von Ärzten und Studenten. Zukünftig eröffnen sich in der Gynäkologie neue Möglichkeiten durch den Einsatz der Telekolposkopie. Since carcinoma of the cervix is one of the most common cancers in women, screening of the cervix has acquired considerable importance. Colposcopy is a simple diagnostic method of detecting suspicious changes at an early stage. Shortcomings of this method are its low specificity and high inter- and intra-observer variability. A clinical pilot study was therefore carried out to investigate the advantages of a digital colposcopic system comprising a binocular colposcope coupled to a CCD camera and a computer. The aim of the study was to evaluate the reliability of diagnostic findings of the cervix obtained with digital colposcopy in comparison with standard binocular colposcopy, and to assess its suitability for telematic applications (teleconsultation, telediagnostics, treaching). A total of 315 patients were examined and statistically analysed. The patients were first submitted to a conventional colposcopic examination and a diagnosis was established. During the colposcopic examination camera images were stored on a computer, on the basis of which a second physician experienced in colposcopy reviewed the initial diagnosis. The primary and secondary findings of each patient were classified into 4 categories and compared following the Rome classification system. Agreement between the primary and secondary diagnosis was established in 69 % of the cases (κ = 0.60 ± 0.03). No bias was observed in terms of under- or overrating. The percentage of non-assessable colposcopic examinations was 9.2%. Digital colposcopy is therefore suitable for reproducing diagnostic findings on the computer, given adequate digital image quality and a suitable classification model. The method has clear advantages with regard to follow-up, internal quality control of the diagnosis, and the training and further education of physicians and students. In the future, telecolposcopy may open up new opportunities in gynaecology. 
540 |a © Walter de Gruyter 
690 7 |a Zervixkarzinom  |2 nationallicence 
690 7 |a digitale Kolposkopie  |2 nationallicence 
690 7 |a Datenbank  |2 nationallicence 
690 7 |a klinische Evaluation  |2 nationallicence 
690 7 |a Telekolposkopie  |2 nationallicence 
690 7 |a Cervical cancer  |2 nationallicence 
690 7 |a digital colposcopy  |2 nationallicence 
690 7 |a data base  |2 nationallicence 
690 7 |a clinical evaluation  |2 nationallicence 
690 7 |a telecolposcopy  |2 nationallicence 
700 1 |a Schädel  |D D.  |u Laser- und Medizin-Technologie GmbH, Berlin.  |4 aut 
700 1 |a Coumbos  |D A.  |u Frauenklinik und Poliklinik der Charité - Universitätsmedizin Berlin, Campus Benjamin Franklin.  |4 aut 
700 1 |a Ey  |D St  |u Laser- und Medizin-Technologie GmbH, Berlin.  |4 aut 
700 1 |a Willrodt  |D R.-G  |u Frauenklinik und Poliklinik der Charité - Universitätsmedizin Berlin, Campus Benjamin Franklin.  |4 aut 
700 1 |a Kühn  |D W.  |u Frauenklinik und Poliklinik der Charité - Universitätsmedizin Berlin, Campus Benjamin Franklin.  |4 aut 
700 1 |a Albrecht  |D H.  |u Laser- und Medizin-Technologie GmbH, Berlin.  |4 aut 
773 0 |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/6(2004-06-01), 157-162  |x 0013-5585  |q 49:6<157  |1 2004  |2 49  |o bmte 
856 4 0 |u https://doi.org/10.1515/BMT.2004.030  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1515/BMT.2004.030  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Schädel  |D D.  |u Laser- und Medizin-Technologie GmbH, Berlin  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Coumbos  |D A.  |u Frauenklinik und Poliklinik der Charité - Universitätsmedizin Berlin, Campus Benjamin Franklin  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ey  |D St  |u Laser- und Medizin-Technologie GmbH, Berlin  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Willrodt  |D R.-G  |u Frauenklinik und Poliklinik der Charité - Universitätsmedizin Berlin, Campus Benjamin Franklin  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kühn  |D W.  |u Frauenklinik und Poliklinik der Charité - Universitätsmedizin Berlin, Campus Benjamin Franklin  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Albrecht  |D H.  |u Laser- und Medizin-Technologie GmbH, Berlin  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/6(2004-06-01), 157-162  |x 0013-5585  |q 49:6<157  |1 2004  |2 49  |o bmte 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter