Experimentelle Untersuchungen zur Reproduzierbarkeit von Ensemble-gemittelten elektromyographischen Ganganalysedaten im Bereich der experimentellen und klinischen Orthopädie

Verfasser / Beitragende:
Experimental Investigation on the Reproducibility of Ensemble Averaged Electromyographic Gait Analysis Data in Experimental and Clinical Orthopaedics / [A Meurer, F Bodem, J Decking, G Lenhard, J Heine]
Ort, Verlag, Jahr:
2004
Enthalten in:
Biomedizinische Technik/Biomedical Engineering, 49/6(2004-06-01), 170-176
Format:
Artikel (online)
ID: 378939998
LEADER caa a22 4500
001 378939998
003 CHVBK
005 20180305123649.0
007 cr unu---uuuuu
008 161128e20040601xx s 000 0 ger
024 7 0 |a 10.1515/BMT.2004.032  |2 doi 
035 |a (NATIONALLICENCE)gruyter-10.1515/BMT.2004.032 
245 0 0 |a Experimentelle Untersuchungen zur Reproduzierbarkeit von Ensemble-gemittelten elektromyographischen Ganganalysedaten im Bereich der experimentellen und klinischen Orthopädie  |h [Elektronische Daten]  |c Experimental Investigation on the Reproducibility of Ensemble Averaged Electromyographic Gait Analysis Data in Experimental and Clinical Orthopaedics / [A Meurer, F Bodem, J Decking, G Lenhard, J Heine] 
520 3 |a Die Oberflächenelektromyographie stellt bei geeignet gewählter Anwendungs- und Auswertungsmethodik für die klinische und experimentelle Orthopädie ein relativ einfach anwendbares Verfahren dar, um den zeitlichen Verlauf der Aktivierung von Skelettmuskeln eines Patienten beim Gehen darzustellen. Es kann damit der Einfluß sowohl von veränderten äußeren Gehbedingungen (z. B. von orthopädisch zugerichtetem Schuhwerk) als auch von krankheits- oder therapiebedingten Veränderungen des Muskuloskeletalsystems auf das individuelle muskuläre Gangbild dargestellt werden. Die Aussagekraft solcher Untersuchungen ist dabei grundsätzlich vom Ausmaß der Reproduzierbarkeit des ganganalytischen Befundes eines Probanden begrenzt, der in unverändertem körperlichem Zustand zu verschiedenen Zeiten unter gleichbleibenden experimentellen Bedingungen untersucht wird. Unsere Experimente zeigten, daß der Grad der Reproduzierbarkeit von elektromyographischen Aktivitätskurven, die durch Ensemblemittelung über eine ausreichend große Zahl von Doppelschritten gewonnen werden, intraindividuell bei verschiedenen Muskeln und interindividuell bei verschiedenen Probanden unterschiedlich ist. Die intraindividuelle Reproduzierbarkeit innerhalb der gleichen experimentellen Sitzung ist sehr hoch und erheblich besser als bei Messungen an verschiedenen Tagen. Die grundsätzliche Charakteristik der Kurvenform ist in experimentellen Sitzungen an verschiedenen Tagen besser reproduzierbar als die absoluten Amplitudenhöhen. Die bei einem Patienten im Verlauf einer operativen oder konservativen Therapie bei gleichen äußeren Versuchsbedingungen ermittelten Unterschiede in ganganalytischen Befunden müssen vor diesem Hintergrund hinsichtlich ihrer tatsächlichen Herkunft sehr sorgfältig interpretiert werden. With suitable application and signal processing methods, surface electromyography is a comparatively simple instrument for investigating the temporal pattern of the muscular activity of a walking subject. The influence of changes both in the external experimental conditions (e.g. orthopedic shoe design) and in the human locomotor system (due to disease or therapy) on the individual muscular gait characteristics can be documented in this way. The usefulness of this kind of investigation is basically limited by the reproducibility of the gait analytical findings of the subject, who is examined at different times with unchanged bodily state and under identical experimental conditions unchanged. In our experiments we observed that the reproducibility of electromyographic activity curves obtained by ensemble averaging over a sufficiently high number of full strides differs for different muscles and in different subjects. Within the same experimental session it is very high and considerably better than in experiments done on different days. In examinations done on different days the basic characteristics of the activity curves are reproduced better than the absolute height of the amplitudes. In view of these findings the differences observed in the gait analysis of patients in the course of operative or conservative therapy have to be interpreted very carefully as to their true origin. 
540 |a © Walter de Gruyter 
690 7 |a Ganganalyse  |2 nationallicence 
690 7 |a EMG  |2 nationallicence 
690 7 |a Ensemblemittelung  |2 nationallicence 
690 7 |a Reproduzierbarkeit  |2 nationallicence 
690 7 |a Gait analysis  |2 nationallicence 
690 7 |a EMG  |2 nationallicence 
690 7 |a Ensemble averaging  |2 nationallicence 
690 7 |a Reproducibility  |2 nationallicence 
700 1 |a Meurer  |D A.  |u Orthopädische Klinik, Klinikum der Johannes Gutenberg-Universität Mainz.  |4 aut 
700 1 |a Bodem  |D F.  |u Orthopädische Klinik, Klinikum der Johannes Gutenberg-Universität Mainz.  |4 aut 
700 1 |a Decking  |D J.  |u Orthopädische Klinik, Klinikum der Johannes Gutenberg-Universität Mainz.  |4 aut 
700 1 |a Lenhard  |D G.  |u Orthopädische Klinik, Klinikum der Johannes Gutenberg-Universität Mainz.  |4 aut 
700 1 |a Heine  |D J.  |u Orthopädische Klinik, Klinikum der Johannes Gutenberg-Universität Mainz.  |4 aut 
773 0 |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/6(2004-06-01), 170-176  |x 0013-5585  |q 49:6<170  |1 2004  |2 49  |o bmte 
856 4 0 |u https://doi.org/10.1515/BMT.2004.032  |q text/html  |z Onlinezugriff via DOI 
908 |D 1  |a research article  |2 jats 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1515/BMT.2004.032  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Meurer  |D A.  |u Orthopädische Klinik, Klinikum der Johannes Gutenberg-Universität Mainz  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Bodem  |D F.  |u Orthopädische Klinik, Klinikum der Johannes Gutenberg-Universität Mainz  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Decking  |D J.  |u Orthopädische Klinik, Klinikum der Johannes Gutenberg-Universität Mainz  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Lenhard  |D G.  |u Orthopädische Klinik, Klinikum der Johannes Gutenberg-Universität Mainz  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Heine  |D J.  |u Orthopädische Klinik, Klinikum der Johannes Gutenberg-Universität Mainz  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Biomedizinische Technik/Biomedical Engineering  |d Walter de Gruyter  |g 49/6(2004-06-01), 170-176  |x 0013-5585  |q 49:6<170  |1 2004  |2 49  |o bmte 
900 7 |b CC0  |u http://creativecommons.org/publicdomain/zero/1.0  |2 nationallicence 
898 |a BK010053  |b XK010053  |c XK010000 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-gruyter