<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">388019271</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180307124919.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161130e199810  xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1557/JMR.1998.0407</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">S0884291400046422</subfield>
   <subfield code="2">pii</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)cambridge-10.1557/JMR.1998.0407</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Monodisperse magnetic nanoparticles: Preparation and dispersion in water and oils</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Nanometric maghemite and cobalt ferrite particles are chemically synthesized. The process produces particles polydisperse in size. The positive charges of their surface allow one to disperse them in aqueous acidic solutions and to obtain dispersions stabilized through electrostatic repulsions. Increasing acid concentration (in the range 0.1 to 0.5 mol.L−1), interparticles repulsions are screened and phase transitions are induced. Using this phenomenon, we describe a two-step size sorting process, in order to get significant amounts of nanometric monosized particles (with diameters monitored between typically 6 and 13 nm). As the surface of the latter is not modified by the size sorting process, usual procedures are used to disperse them in several aqueous or oily media.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Copyright © Materials Research Society 1998</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Lefebure</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Laboratoire Liquides Ioniques et Interfaces Chargées, Equipe &quot;Colloïdes Magnétiques,” Université Pierre et Marie Curie, Paris, France</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Dubois</subfield>
   <subfield code="D">E.</subfield>
   <subfield code="u">Laboratoire Liquides Ioniques et Interfaces Chargées, Equipe &quot;Colloïdes Magnétiques,” Université Pierre et Marie Curie, Paris, France</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Cabuil</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">Laboratoire Liquides Ioniques et Interfaces Chargées, Equipe &quot;Colloïdes Magnétiques,” Université Pierre et Marie Curie, Paris, France</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Neveu</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Laboratoire Liquides Ioniques et Interfaces Chargées, Equipe &quot;Colloïdes Magnétiques,” Université Pierre et Marie Curie, Paris, France</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Massart</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Laboratoire Liquides Ioniques et Interfaces Chargées, Equipe &quot;Colloïdes Magnétiques,” Université Pierre et Marie Curie, Paris, France</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Materials Research</subfield>
   <subfield code="d">Cambridge University Press</subfield>
   <subfield code="g">13/10(1998-10), 2975-2981</subfield>
   <subfield code="x">0884-2914</subfield>
   <subfield code="q">13:10&lt;2975</subfield>
   <subfield code="1">1998</subfield>
   <subfield code="2">13</subfield>
   <subfield code="o">JMR</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1557/JMR.1998.0407</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1557/JMR.1998.0407</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Lefebure</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Laboratoire Liquides Ioniques et Interfaces Chargées, Equipe &quot;Colloïdes Magnétiques,” Université Pierre et Marie Curie, Paris, France</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Dubois</subfield>
   <subfield code="D">E.</subfield>
   <subfield code="u">Laboratoire Liquides Ioniques et Interfaces Chargées, Equipe &quot;Colloïdes Magnétiques,” Université Pierre et Marie Curie, Paris, France</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Cabuil</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">Laboratoire Liquides Ioniques et Interfaces Chargées, Equipe &quot;Colloïdes Magnétiques,” Université Pierre et Marie Curie, Paris, France</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Neveu</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Laboratoire Liquides Ioniques et Interfaces Chargées, Equipe &quot;Colloïdes Magnétiques,” Université Pierre et Marie Curie, Paris, France</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Massart</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Laboratoire Liquides Ioniques et Interfaces Chargées, Equipe &quot;Colloïdes Magnétiques,” Université Pierre et Marie Curie, Paris, France</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Materials Research</subfield>
   <subfield code="d">Cambridge University Press</subfield>
   <subfield code="g">13/10(1998-10), 2975-2981</subfield>
   <subfield code="x">0884-2914</subfield>
   <subfield code="q">13:10&lt;2975</subfield>
   <subfield code="1">1998</subfield>
   <subfield code="2">13</subfield>
   <subfield code="o">JMR</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="b">CC0</subfield>
   <subfield code="u">http://creativecommons.org/publicdomain/zero/1.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-cambridge</subfield>
  </datafield>
 </record>
</collection>
