<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     cad a22        4500</leader>
  <controlfield tag="001">390147974</controlfield>
  <controlfield tag="005">20200501042436.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161201e201606  xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.5167/uzh-128189</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1097/ID.0000000000000419</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(ZORA)oai:www.zora.uzh.ch:128189</subfield>
  </datafield>
  <datafield tag="084" ind1=" " ind2=" ">
   <subfield code="a">610</subfield>
   <subfield code="2">ddc</subfield>
  </datafield>
  <datafield tag="091" ind1=" " ind2=" ">
   <subfield code="a">27213528</subfield>
   <subfield code="b">pmid</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Effect of Different Abutments and Connections in Deformation Crestal Bone</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Alfredo Mikail Melo Mesquita, Juliano H M Silva, Cintia Helena Cury Saraceni, Alberto N Kojima, Mutlu Özcan]</subfield>
  </datafield>
  <datafield tag="506" ind1=" " ind2=" ">
   <subfield code="a">openAccess</subfield>
   <subfield code="2">eu-repo</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">STATEMENT OF PROBLEM  The use of Morse taper connections is increasing, but little is known about the biomechanical use of abutments and their use in fixed prostheses.  PURPOSE  This study evaluated the transmission of load on the bone implant-supported dentures, varying the type of prosthetic connection and abutment.  MATERIAL AND METHODS  Using 4 polyurethane models, 3 implants were inserted into each block, establishing the following groups: (a) external hexagon and Micro-Unit abutments; (b) external hexagon and UCLA abutment; (c) Morse taper and Micro-Unit abutments; and (d) Morse taper and UCLA abutments. The prosthetic structures were cast, and in a universal testing machine, load was applied midway between the implants, with cantilever intervals of 5, 10, 15, 20, and 25 mm. Data were analyzed by Mann-Whitney, Friedman, and Kruskal-Wallis tests (P &lt; 0.05).  RESULTS  Regarding the prosthetic connection, there was no difference in the use of hexagonal or Morse taper, but the use of Micro-Unit abutment showed lower deformation values than UCLA for the 2 connections.  CONCLUSIONS  The use of intermediate abutments affects the distribution of masticatory loads: the greater the length of the cantilever, the greater the surface deformation of the bone around the distal implant.</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Clinic of Reconstructive Dentistry</subfield>
   <subfield code="2">zora</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Mesquita</subfield>
   <subfield code="D">Alfredo Mikail Melo</subfield>
   <subfield code="e">joint author</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Silva</subfield>
   <subfield code="D">Juliano H M.</subfield>
   <subfield code="e">joint author</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Saraceni</subfield>
   <subfield code="D">Cintia Helena Cury</subfield>
   <subfield code="e">joint author</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kojima</subfield>
   <subfield code="D">Alberto N.</subfield>
   <subfield code="e">joint author</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Özcan</subfield>
   <subfield code="D">Mutlu</subfield>
   <subfield code="e">joint author</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Implant Dentistry</subfield>
   <subfield code="g">25(3):328-334</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://www.zora.uzh.ch/id/eprint/128189/1/Superficial%20deformation%20in%20bone%20for%20prosthesis_acc.pdf</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">WWW-Backlink auf das Repository</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">Journal Article</subfield>
   <subfield code="z">PeerReviewed</subfield>
   <subfield code="2">zora</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">ZORA</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://www.zora.uzh.ch/id/eprint/128189/1/Superficial%20deformation%20in%20bone%20for%20prosthesis_acc.pdf</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">WWW-Backlink auf das Repository</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">ZORA</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Mesquita</subfield>
   <subfield code="D">Alfredo Mikail Melo</subfield>
   <subfield code="e">joint author</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">ZORA</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Silva</subfield>
   <subfield code="D">Juliano H M.</subfield>
   <subfield code="e">joint author</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">ZORA</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Saraceni</subfield>
   <subfield code="D">Cintia Helena Cury</subfield>
   <subfield code="e">joint author</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">ZORA</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kojima</subfield>
   <subfield code="D">Alberto N.</subfield>
   <subfield code="e">joint author</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">ZORA</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Özcan</subfield>
   <subfield code="D">Mutlu</subfield>
   <subfield code="e">joint author</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">ZORA</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Implant Dentistry</subfield>
   <subfield code="g">25(3):328-334</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">ZORA</subfield>
   <subfield code="F">ZORA</subfield>
   <subfield code="b">ZORA</subfield>
   <subfield code="j">Journal Article</subfield>
   <subfield code="c">openAccess</subfield>
  </datafield>
 </record>
</collection>
