<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">39750215X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180308164535.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161202e19950701xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1093/oxfordjournals.rpd.a082722</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">0144-8420</subfield>
   <subfield code="2">pii</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)oxford-10.1093/oxfordjournals.rpd.a082722</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Effectiveness of Finish Materials and Room Air-Conditioner on the Reduction of Indoor Radon Concentration in Hong Kong</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[A.K. Ma, C.K Man, E. Ho, S.W. Pang]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Four different kinds of finish material were investigated: wallpaper, paint, plaster and tile. When applied to the bare concrete walls of uninhabited rooms in flats of a building under construction, all of them were found to reduce indoor radon concentration. The magnitude of reduction by these finish materials ranged from 20% to 80%. Wallpaper was found to provide the best protection against radon emission from bare concrete walls in a bedroom with a size of 19.3 m3. Wallpaper can reduce the indoor radon concentration about twice as much as paint (water-based) or plaster in this investigation. Tile was also found to be a good material against radon emission from concrete walls in a bathroom with a size of 6.3 m3. Indoor radon concentration was found to decrease with elevation from the ground level, and was affected strongly by mechanical ventilation. Another 30% to 50% reduction in indoor radon concentration in addition to finish material can be achieved by a room air-conditioner, simply by turning the fan on and setting it in the 'high' position. It was also found that indoor radon concentrations were not affected by turning the fresh air shutter to the 'on' or 'off' positions in the room air-conditioner.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Radiation Protection Dosimetry</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ma</subfield>
   <subfield code="D">A.K.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Man</subfield>
   <subfield code="D">C.K.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ho</subfield>
   <subfield code="D">E.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Pang</subfield>
   <subfield code="D">S.W.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Radiation Protection Dosimetry</subfield>
   <subfield code="d">Oxford University Press</subfield>
   <subfield code="g">60/3(1995-07-01), 237-241</subfield>
   <subfield code="x">0144-8420</subfield>
   <subfield code="q">60:3&lt;237</subfield>
   <subfield code="1">1995</subfield>
   <subfield code="2">60</subfield>
   <subfield code="o">rpd</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1093/oxfordjournals.rpd.a082722</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1093/oxfordjournals.rpd.a082722</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ma</subfield>
   <subfield code="D">A.K.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Man</subfield>
   <subfield code="D">C.K.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ho</subfield>
   <subfield code="D">E.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Pang</subfield>
   <subfield code="D">S.W.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Radiation Protection Dosimetry</subfield>
   <subfield code="d">Oxford University Press</subfield>
   <subfield code="g">60/3(1995-07-01), 237-241</subfield>
   <subfield code="x">0144-8420</subfield>
   <subfield code="q">60:3&lt;237</subfield>
   <subfield code="1">1995</subfield>
   <subfield code="2">60</subfield>
   <subfield code="o">rpd</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">CC BY-NC-4.0</subfield>
   <subfield code="u">http://creativecommons.org/licenses/by-nc/4.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-oxford</subfield>
  </datafield>
 </record>
</collection>
