<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">397502214</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180308164535.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161202e19950201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1093/oxfordjournals.rpd.a082613</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">0144-8420</subfield>
   <subfield code="2">pii</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)oxford-10.1093/oxfordjournals.rpd.a082613</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="3">
   <subfield code="a">An Evaluation of Hydrogen as a TEPC Counting Gas in Radiation Protection Microdosimetry</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[R. Khaloo, A.J. Waker]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Tissue-equivalent proportional counters (TEPC) filled with conventional tissue-equivalent gases have a significantly low neutron dose equivalent response in the neutron energy region between thermal and about 200 keV. Theoretical modelling for monoenergetic neutron fields suggests that using pure hydrogen as a microdosimetric counting gas would improve the dose equivalent response. Average neutron dose equivalent response calculations have been done for selected realistic broad energy neutron fields and are found generally to support this suggestion. Gas gain investigations performed with conventional tissue-equivalent gases and hydrogen indicate that hydrogen has only a limited region of applied voltage, up to a reduced electric field at the anode of about 600 V.cm-1.torr-1. Microdosimetric measurements performed with hydrogen as the counting gas nevertheless demonstrate that it is suitable for measuring event-size spectra and carrying out quantitative dosimetry. The non-tissue-equivalent nature of hydrogen, however, does present some difficulties in calibration and interpretation of the measured spectra. Taking into account the non-tissue-equivalence and the poor gas gain characteristics of hydrogen the advantage of using this counting gas, at least in its unadulterated form, appears marginal. However, if TEPC ambient dose equivalent responses are found to be lower than that predicted by the theoretical model used here for workplace neutron fields, then it may become an attractive option to use hydrogen. In this case effort will be required to improve the gas gain characteristic of hydrogen by investigating the effect of small admixtures of quenching gases.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Radiation Protection Dosimetry</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Khaloo</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Waker</subfield>
   <subfield code="D">A.J.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Radiation Protection Dosimetry</subfield>
   <subfield code="d">Oxford University Press</subfield>
   <subfield code="g">58/3(1995-02-01), 185-191</subfield>
   <subfield code="x">0144-8420</subfield>
   <subfield code="q">58:3&lt;185</subfield>
   <subfield code="1">1995</subfield>
   <subfield code="2">58</subfield>
   <subfield code="o">rpd</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1093/oxfordjournals.rpd.a082613</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1093/oxfordjournals.rpd.a082613</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Khaloo</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Waker</subfield>
   <subfield code="D">A.J.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Radiation Protection Dosimetry</subfield>
   <subfield code="d">Oxford University Press</subfield>
   <subfield code="g">58/3(1995-02-01), 185-191</subfield>
   <subfield code="x">0144-8420</subfield>
   <subfield code="q">58:3&lt;185</subfield>
   <subfield code="1">1995</subfield>
   <subfield code="2">58</subfield>
   <subfield code="o">rpd</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">CC BY-NC-4.0</subfield>
   <subfield code="u">http://creativecommons.org/licenses/by-nc/4.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-oxford</subfield>
  </datafield>
 </record>
</collection>
