<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">39750439X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180308164540.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">161202e19950301xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1093/oxfordjournals.rpd.a082634</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">0144-8420</subfield>
   <subfield code="2">pii</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)oxford-10.1093/oxfordjournals.rpd.a082634</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Arvela</subfield>
   <subfield code="D">H.</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Seasonal Variation in Radon Concentration of 3000 Dwellings with Model Comparisons</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[H. Arvela]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Indoor radon concentration of two consecutive half-year measuring period in 3074 Finnish dwellings were analysed. The periods were the warmest and coldest half-year periods in Finland. The mean of winter/summer concentration ratio in all low-rise residential buildings was 1.28, and in houses with winter concentrations of &lt;50, 50-100, 100-200 and &gt;200 Bq.m-3, 0.97, 1.22, 1.34 and 1.55, respectively. The results are in agreement with the results predicted by the model, which takes into account the varying contribution of diffusive and convective radon entry as well as the contribution of stack effect and wind induced air infiltration. The model is a useful tool for estimating the average correction factor for the annual average radon concentration from the two months measurements used in Finland. Typical correction factors vary in the range of 1.0-0.7, depending on the outdoor temperature and on radon concentration levels. Model comparison with winter/summer ratios measured in houses with slab on grade suggests an average diffusive radon entry rate of 7 Bq.m-3.h-1 and a convective entry rate of 50 Bq.m-3.h-1 at an average indoor/outdoor temperature difference of 17K. The use of a simple averaging of winter/summer ratios for houses with varying radon levels, creates inaccuracy in the information on seasonal variation. Surprisingly, the behaviour of the winter/summer ratio in blocks of flats was very similar to that in low-rise residential buildings. The results support the interpretation that soil air leakage also contributes unexpectedly to the radon concentration in flats.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Radiation Protection Dosimetry</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Radiation Protection Dosimetry</subfield>
   <subfield code="d">Oxford University Press</subfield>
   <subfield code="g">59/1(1995-03-01), 33-42</subfield>
   <subfield code="x">0144-8420</subfield>
   <subfield code="q">59:1&lt;33</subfield>
   <subfield code="1">1995</subfield>
   <subfield code="2">59</subfield>
   <subfield code="o">rpd</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1093/oxfordjournals.rpd.a082634</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1093/oxfordjournals.rpd.a082634</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Arvela</subfield>
   <subfield code="D">H.</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Radiation Protection Dosimetry</subfield>
   <subfield code="d">Oxford University Press</subfield>
   <subfield code="g">59/1(1995-03-01), 33-42</subfield>
   <subfield code="x">0144-8420</subfield>
   <subfield code="q">59:1&lt;33</subfield>
   <subfield code="1">1995</subfield>
   <subfield code="2">59</subfield>
   <subfield code="o">rpd</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">CC BY-NC-4.0</subfield>
   <subfield code="u">http://creativecommons.org/licenses/by-nc/4.0</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-oxford</subfield>
  </datafield>
 </record>
</collection>
