<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445296763</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317142544.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20100401xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s12243-009-0131-0</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s12243-009-0131-0</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Extension of the FDTD Huygens subgridding to frequency dependent media</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Fumie Costen, Jean-Pierre Bérenger]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A wide range of wireless system developments require knowledge of the distribution of electromagnetic fields from various sources in humans. As experimental assessment is ethically unacceptable, high-resolution numerical dosimetry is needed. The finite-difference time-domain method is the most appropriate due to its simplicity and versatility. Reduction in demands on computational resources can be achieved using subgridding techniques. This paper rigorously introduces frequency dependency to one of the most promising subgridding techniques, Huygens subgridding. The validity of the Huygens surface in lossy media, as well as on the physical interface, is intensively studied.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Institut TELECOM and Springer-Verlag, 2009</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Huygens surface</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Subgrid</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Finite-difference time-domain</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Debye media</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">UWB</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Numerical method</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Numerical dosimetry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Costen</subfield>
   <subfield code="D">Fumie</subfield>
   <subfield code="u">School of Electrical and Electronic Engineering, The University of Manchester, Sackville Street Building, M60 1QD, Manchester, UK</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Bérenger</subfield>
   <subfield code="D">Jean-Pierre</subfield>
   <subfield code="u">Centre d'Analyse de Défense, 16 bis, Avenue Prieur de la Côte d'Or, 94114, Arcueil, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">annals of telecommunications - annales des télécommunications</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">65/3-4(2010-04-01), 211-217</subfield>
   <subfield code="x">0003-4347</subfield>
   <subfield code="q">65:3-4&lt;211</subfield>
   <subfield code="1">2010</subfield>
   <subfield code="2">65</subfield>
   <subfield code="o">12243</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s12243-009-0131-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s12243-009-0131-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Costen</subfield>
   <subfield code="D">Fumie</subfield>
   <subfield code="u">School of Electrical and Electronic Engineering, The University of Manchester, Sackville Street Building, M60 1QD, Manchester, UK</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Bérenger</subfield>
   <subfield code="D">Jean-Pierre</subfield>
   <subfield code="u">Centre d'Analyse de Défense, 16 bis, Avenue Prieur de la Côte d'Or, 94114, Arcueil, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">annals of telecommunications - annales des télécommunications</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">65/3-4(2010-04-01), 211-217</subfield>
   <subfield code="x">0003-4347</subfield>
   <subfield code="q">65:3-4&lt;211</subfield>
   <subfield code="1">2010</subfield>
   <subfield code="2">65</subfield>
   <subfield code="o">12243</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
