<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">44530443X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317142608.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20100601xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s13246-010-0013-9</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s13246-010-0013-9</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Harvey</subfield>
   <subfield code="D">Steven</subfield>
   <subfield code="u">Department of Nuclear Medicine, Wollongong Hospital, Crown Street, 2500, Wollongong, NSW, Australia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Measurement of scatter radiation from the GE Infinia Hawkeye 4 SPECT/CT system</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Steven Harvey]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">In this study the cumulative scatter dose from a typical monthly SPECT/CT workload on a new GE Infinia Hawkeye 4 system was measured by means of a dosimeter badge survey. Doses were found to be well within regulatory limits. Scatter dose rates attributable solely to the CT component were also measured experimentally for comparison with the manufacturer's isocontour plot. The measured CT dose rate isocontours were found to be of similar magnitude and location to those quoted by the manufacturer. Data generated from this study will form a valuable baseline for the monitoring of equipment performance and for future scatter radiation measurements.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Australasian College of Physical Scientists and Engineers in Medicine, 2010</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">SPECT-CT</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Scatter radiation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Hawkeye</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Australasian Physical &amp; Engineering Sciences in Medicine</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">33/2(2010-06-01), 193-197</subfield>
   <subfield code="x">0158-9938</subfield>
   <subfield code="q">33:2&lt;193</subfield>
   <subfield code="1">2010</subfield>
   <subfield code="2">33</subfield>
   <subfield code="o">13246</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s13246-010-0013-9</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s13246-010-0013-9</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Harvey</subfield>
   <subfield code="D">Steven</subfield>
   <subfield code="u">Department of Nuclear Medicine, Wollongong Hospital, Crown Street, 2500, Wollongong, NSW, Australia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Australasian Physical &amp; Engineering Sciences in Medicine</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">33/2(2010-06-01), 193-197</subfield>
   <subfield code="x">0158-9938</subfield>
   <subfield code="q">33:2&lt;193</subfield>
   <subfield code="1">2010</subfield>
   <subfield code="2">33</subfield>
   <subfield code="o">13246</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
