<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445316829</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317142650.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110501xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10749-011-0226-4</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10749-011-0226-4</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Diagnostics of the insulation of high-pressure oil-filled 220- and 500-KV cable lines when operating in hydroelectric power plant</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[A. Lubkov, I. Privalov, V. Mezgin]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A procedure for the diagnostics of the insulation of high-pressure oil-filled 220kV and 500kV cable lines approved for use in hydroelectric power plant is presented. The results of the diagnostics and estimation of the residual life of the insulation of such cables, which have been operating for a considerable time in the Toktogul'skaya, Nizhnekamskaya and Bratskaya hydroelectric power plant, are presented.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Science+Business Media, Inc., 2011</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">cable lines</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">oil-filled cable</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">insulation diagnostics</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">residual life</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Lubkov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">JSC &quot;NIIPT”, St. Petersburg, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Privalov</subfield>
   <subfield code="D">I.</subfield>
   <subfield code="u">JSC &quot;NIIPT”, St. Petersburg, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Mezgin</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">Kyrgyz Power Research and Development Center of the Ministry of Power of the Kyrgyzstan Republic (KNTTs &quot;Énergiya”), Bishkek, Kyrgyzstan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Power Technology and Engineering</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">45/1(2011-05-01), 69-75</subfield>
   <subfield code="x">1570-145X</subfield>
   <subfield code="q">45:1&lt;69</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">45</subfield>
   <subfield code="o">10749</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10749-011-0226-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10749-011-0226-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Lubkov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">JSC &quot;NIIPT”, St. Petersburg, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Privalov</subfield>
   <subfield code="D">I.</subfield>
   <subfield code="u">JSC &quot;NIIPT”, St. Petersburg, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Mezgin</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">Kyrgyz Power Research and Development Center of the Ministry of Power of the Kyrgyzstan Republic (KNTTs &quot;Énergiya”), Bishkek, Kyrgyzstan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Power Technology and Engineering</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">45/1(2011-05-01), 69-75</subfield>
   <subfield code="x">1570-145X</subfield>
   <subfield code="q">45:1&lt;69</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">45</subfield>
   <subfield code="o">10749</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
