<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445317272</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317142651.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110701xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10749-011-0240-6</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10749-011-0240-6</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="4">
   <subfield code="a">The reliability of the gas-filled 110 - 750kV circuit breaker units of substations</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Yu. Dementyev, M. Misrikhanov, E. Stolyarov, A. Abdurakhmanov, V. Fedorov, A. Shuntov]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Statistical data on the operating reliability of 110 - 750kV gas-filled circuit breaker units in the substations of the unified national electric power grid are analyzed. The structure of outages and planned downtimes of the elements of the units, namely, the circuit breaker and its actuator, the equipment of the unit (the current and voltage transformers, the disconnectors etc.), buses and secondary circuits, are presented. Proposals for increasing the reliability of distributors are substantiated.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Science+Business Media, Inc., 2011</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">gas-filled circuit breaker</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">distributor</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">reliability</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Dementyev</subfield>
   <subfield code="D">Yu</subfield>
   <subfield code="u">JSC &quot;Federal Grid Company of Unified Energy System”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Misrikhanov</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">JSC &quot;Federal Grid Company of Unified Energy System”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Stolyarov</subfield>
   <subfield code="D">E.</subfield>
   <subfield code="u">JSC &quot;Federal Grid Company of Unified Energy System”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Abdurakhmanov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">JSC &quot;Specialized design office of Renovation and Reconstruction”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Fedorov</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">JSC &quot;Specialized design office of Renovation and Reconstruction”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Shuntov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">JSC &quot;Specialized design office of Renovation and Reconstruction”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Power Technology and Engineering</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">45/2(2011-07-01), 151-154</subfield>
   <subfield code="x">1570-145X</subfield>
   <subfield code="q">45:2&lt;151</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">45</subfield>
   <subfield code="o">10749</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10749-011-0240-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10749-011-0240-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Dementyev</subfield>
   <subfield code="D">Yu</subfield>
   <subfield code="u">JSC &quot;Federal Grid Company of Unified Energy System”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Misrikhanov</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">JSC &quot;Federal Grid Company of Unified Energy System”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Stolyarov</subfield>
   <subfield code="D">E.</subfield>
   <subfield code="u">JSC &quot;Federal Grid Company of Unified Energy System”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Abdurakhmanov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">JSC &quot;Specialized design office of Renovation and Reconstruction”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Fedorov</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">JSC &quot;Specialized design office of Renovation and Reconstruction”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Shuntov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">JSC &quot;Specialized design office of Renovation and Reconstruction”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Power Technology and Engineering</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">45/2(2011-07-01), 151-154</subfield>
   <subfield code="x">1570-145X</subfield>
   <subfield code="q">45:2&lt;151</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">45</subfield>
   <subfield code="o">10749</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
