<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445317361</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317142652.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110301xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10749-011-0214-8</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10749-011-0214-8</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="4">
   <subfield code="a">The prevention of the formation of glazed frost on an overhead transmission line without disconnecting the line</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[V. Sorokin, L. Dorozhko]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Existing systems for melting glazed frost on overhead electric transmission lines are analyzed. To prevent the formation of glazed frost, without disconnecting the line, it is proposed to insert an appropriate voltage-boosting transformer into the line. The effectiveness of such a system of preventing the formation of glazed frost in a specific network is demonstrated.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Science+Business Media, Inc., 2011</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">overhead transmission lines</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">glazed frost</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">reactive current</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">line disconnection</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">voltage-boosting transformers</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">voltage normalization</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Sorokin</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">JSC &quot;G. M. Krzhizhanovskii Power Institute”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Dorozhko</subfield>
   <subfield code="D">L.</subfield>
   <subfield code="u">JSC &quot;G. M. Krzhizhanovskii Power Institute”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Power Technology and Engineering</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">44/6(2011-03-01), 498-501</subfield>
   <subfield code="x">1570-145X</subfield>
   <subfield code="q">44:6&lt;498</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">44</subfield>
   <subfield code="o">10749</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10749-011-0214-8</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10749-011-0214-8</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Sorokin</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">JSC &quot;G. M. Krzhizhanovskii Power Institute”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Dorozhko</subfield>
   <subfield code="D">L.</subfield>
   <subfield code="u">JSC &quot;G. M. Krzhizhanovskii Power Institute”, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Power Technology and Engineering</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">44/6(2011-03-01), 498-501</subfield>
   <subfield code="x">1570-145X</subfield>
   <subfield code="q">44:6&lt;498</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">44</subfield>
   <subfield code="o">10749</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
