<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445347872</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317142835.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20111001xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00056-011-0039-y</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00056-011-0039-y</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Influence of various polishing methods on pulp temperature</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="b">An in vitro study</subfield>
   <subfield code="c">[S. Mank, M. Steineck, L. Brauchli]</subfield>
  </datafield>
  <datafield tag="246" ind1="1" ind2=" ">
   <subfield code="a">Einfluss verschiedener Poliermethoden auf die Pulpatemperatur</subfield>
   <subfield code="b">Eine In-vitro-Studie</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Objective: After orthodontic debonding, adhesive removal can lead to rises in pulp temperature, causing histological changes or pulp necrosis. The objective of this study was to measure increases in pulp temperature during adhesive removal using different instruments and various cooling procedures. Materials and methods: A thermoelement was introduced into the pulp chamber of 10human incisors. The teeth were immersed in a 36°C water bath up to the cementoenamel junction. Two carbide burs, one polishing disk and two rubber points were used for polishing. All measurements were taken over a 10s period by a single investigator, under slight pressure and with constant motion. Three cooling procedures were examined: no cooling, air cooling and water cooling. Pulp temperatures were measured before polishing and after 10s of polishing. Results: Without cooling, the two rubber points revealed clinically relevant temperature increases of 6.1°C and 12.4°C. Cooling with air and with water reduced pulp temperature in conjunction with all polishing methods. Air cooling was most efficient, except in combination with the polishing disk. Conclusion: Under these study conditions, carbide burs and polishing disks can be used safely and without risk to the pulp, even without cooling. On the other hand, rubber points cause a marked increase in pulp temperature when used without cooling.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Urban &amp;amp; Vogel, Muenchen, 2011</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Pulp temperature</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Adhesive removal</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Polishing methods</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Pulpatemperatur</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Adhäsiventfernung</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Poliermethoden</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Mank</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Clinic for Orthodontics and Pediatric Dentistry, University of Basel, Hebelstr. 3, 4056, Basel, Switzerland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Steineck</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Clinic for Orthodontics and Pediatric Dentistry, University of Basel, Hebelstr. 3, 4056, Basel, Switzerland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Brauchli</subfield>
   <subfield code="D">L.</subfield>
   <subfield code="u">Clinic for Orthodontics and Pediatric Dentistry, University of Basel, Hebelstr. 3, 4056, Basel, Switzerland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">72/5(2011-10-01), 348-357</subfield>
   <subfield code="x">1434-5293</subfield>
   <subfield code="q">72:5&lt;348</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">72</subfield>
   <subfield code="o">56</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00056-011-0039-y</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00056-011-0039-y</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Mank</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Clinic for Orthodontics and Pediatric Dentistry, University of Basel, Hebelstr. 3, 4056, Basel, Switzerland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Steineck</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Clinic for Orthodontics and Pediatric Dentistry, University of Basel, Hebelstr. 3, 4056, Basel, Switzerland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Brauchli</subfield>
   <subfield code="D">L.</subfield>
   <subfield code="u">Clinic for Orthodontics and Pediatric Dentistry, University of Basel, Hebelstr. 3, 4056, Basel, Switzerland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">72/5(2011-10-01), 348-357</subfield>
   <subfield code="x">1434-5293</subfield>
   <subfield code="q">72:5&lt;348</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">72</subfield>
   <subfield code="o">56</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
