<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445347910</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317142835.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110401xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00056-011-0015-6</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00056-011-0015-6</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Pilot study on accuracy and dimensional stability of impression materials using industrial CT technology</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[S. Steinhäuser-Andresen, A. Detterbeck, C. Funk, M. Krumm, S. Kasperl, A. Holst, U. Hirschfelder]</subfield>
  </datafield>
  <datafield tag="246" ind1="1" ind2=" ">
   <subfield code="a">Pilotstudie zur Genauigkeit und Dimensionsstabilität von Abformmaterialien mittels industrieller CT-Messungen</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Objective: Using computed tomography, scan impressions can be saved and edited as virtual data. The aim of this study was to evaluate the parameters influencing different impression materials and impression trays and their relevance with regard to accuracy and dimensional stability. Materials and methods: Two alginate impressions (Zhermack Hydrogum®5 and Kaniedenta Tetrachrom®) and a polyether impression (3MEspe Impregum™) were each combined with two acrylic trays (3M Espe Position Tray™ and Profimed Opti-Tray) and CT scanned immediately after impression at the Fraunhofer Institute Development Center for X-ray Technology (EZRT) in Fürth, Germany. Each impression was digitized 10 times on the same day, 3 times after 2 days and twice after 6 days, thus determining the dimensional stability of the various materials. An acrylic model was digitized with a high-resolution µCT research scanner to be used as a reference for assessing the accuracy of the impression materials. For graphic and statistical analysis, VGStudio Max® was used. Results: Both alginate impressions were less dimensionally stable than the polyether impression material. The Zhermack Hydrogum®5 alginate impression resulted in more deviation (151µm) after 6 days than the Kaniedenta Tetrachrom® impression. The polyether scans showed a mean deviation of 73µm. The accuracy of both alginates was similarly precise (mean value: Hydrogum®5 0.129 ± 0.021mm, Tetrachrom® 0.137 ± 0.002mm). The type of tray had limited influence on the results of the alginate impressions, while the accuracy of the Impregum™ impression depended on the tray combination chosen. Conclusion: The accuracy of the alginate impressions is sufficient for clinical use in orthodontics and produced, with correct storage, acceptable results even after 2 days. Hydrogum®5 impressions proved to be slightly more accurate than the reference material but less dimensionally stable than the Tetrachrom® impressions. The 3M Espe Position Tray™ seemed to be more practical due to a better retentive effect compared to the Opti-Tray made by Profimed.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Urban &amp;amp; Vogel, Muenchen, 2011</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Computed tomography</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Dental casts</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Digital models</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Impression materials</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Accuracy</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Dimensional stability</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Computertomographie</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Dentale Modelle</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Digitale Modelle</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Abformmaterialien</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Genauigkeit</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Dimensionsstabilität</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Steinhäuser-Andresen</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Zahnklinik 3 - Kieferorthopädie, Friedrich-Alexander-Universität Erlangen-Nürnberg, Glücksstr.11, 91054, Erlangen, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Detterbeck</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Zahnklinik 3 - Kieferorthopädie, Friedrich-Alexander-Universität Erlangen-Nürnberg, Glücksstr.11, 91054, Erlangen, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Funk</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">Fraunhofer-Instituts für Integrierte Schaltungen IIS, Entwicklungszentrum Röntgentechnik (EZRT), Fürth, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Krumm</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Fraunhofer-Instituts für Integrierte Schaltungen IIS, Entwicklungszentrum Röntgentechnik (EZRT), Fürth, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kasperl</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Fraunhofer-Instituts für Integrierte Schaltungen IIS, Entwicklungszentrum Röntgentechnik (EZRT), Fürth, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Holst</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Zahnklinik 3 - Kieferorthopädie, Friedrich-Alexander-Universität Erlangen-Nürnberg, Glücksstr.11, 91054, Erlangen, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hirschfelder</subfield>
   <subfield code="D">U.</subfield>
   <subfield code="u">Zahnklinik 3 - Kieferorthopädie, Friedrich-Alexander-Universität Erlangen-Nürnberg, Glücksstr.11, 91054, Erlangen, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">72/2(2011-04-01), 111-124</subfield>
   <subfield code="x">1434-5293</subfield>
   <subfield code="q">72:2&lt;111</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">72</subfield>
   <subfield code="o">56</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00056-011-0015-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00056-011-0015-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Steinhäuser-Andresen</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Zahnklinik 3 - Kieferorthopädie, Friedrich-Alexander-Universität Erlangen-Nürnberg, Glücksstr.11, 91054, Erlangen, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Detterbeck</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Zahnklinik 3 - Kieferorthopädie, Friedrich-Alexander-Universität Erlangen-Nürnberg, Glücksstr.11, 91054, Erlangen, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Funk</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">Fraunhofer-Instituts für Integrierte Schaltungen IIS, Entwicklungszentrum Röntgentechnik (EZRT), Fürth, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Krumm</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Fraunhofer-Instituts für Integrierte Schaltungen IIS, Entwicklungszentrum Röntgentechnik (EZRT), Fürth, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kasperl</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Fraunhofer-Instituts für Integrierte Schaltungen IIS, Entwicklungszentrum Röntgentechnik (EZRT), Fürth, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Holst</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Zahnklinik 3 - Kieferorthopädie, Friedrich-Alexander-Universität Erlangen-Nürnberg, Glücksstr.11, 91054, Erlangen, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hirschfelder</subfield>
   <subfield code="D">U.</subfield>
   <subfield code="u">Zahnklinik 3 - Kieferorthopädie, Friedrich-Alexander-Universität Erlangen-Nürnberg, Glücksstr.11, 91054, Erlangen, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">72/2(2011-04-01), 111-124</subfield>
   <subfield code="x">1434-5293</subfield>
   <subfield code="q">72:2&lt;111</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">72</subfield>
   <subfield code="o">56</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
