<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445374616</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317142959.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110401xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00540-011-1098-3</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00540-011-1098-3</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Preoxygenation with 20º head-up tilt provides longer duration of non-hypoxic apnea than conventional preoxygenation in non-obese healthy adults</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Venkateswaran Ramkumar, Goneppanavar Umesh, Frenny Philip]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Purpose: Failed airway is the anesthesiologist's nightmare. Although conventional preoxygenation can provide time, atelectasis occurs in the dependent areas of the lungs immediately after anesthetic induction. Therefore, alternatives such as positive end-expiratory pressure (PEEP) and head-up tilt during preoxygenation have been explored. We compared the conventional preoxygenation technique (group C) with 20º head-up tilt (group H) and 5cmH2O PEEP (group P) in non-obese individuals for non-hypoxic apnea duration. Methods: A total of 45 patients were enrolled (15 in each group). After 5min of preoxygenation, intubation was performed after induction of anesthesia with thiopentone and succinylcholine. After confirming the tracheal intubation by esophageal detector device and capnogram, all patients were administered vecuronium to maintain neuromuscular blockade and midazolam to prevent awareness. Post-induction, patients in all groups were left apneic in supine position with the tracheal tube exposed to atmosphere till the SpO2 dropped to 93% or 10min of safe apnea was achieved. Results: The demographic data were comparable. Non-hypoxic apnea duration was higher with group H (452±71s) compared to group C (364±83s, P = 0.030). Group P did not show significant increase in the duration of non-hypoxic apnea (413±86s). There were no adverse outcomes or events. Conclusions: Preoxygenation is clinically and statistically more efficacious and by inference more efficient in the 20º head-up position than with conventional technique in non-obese healthy adults. Although application of 5cmH2O PEEP provides longer duration of non-hypoxic apnea compared to conventional technique, it is not statistically significant.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Japanese Society of Anesthesiologists, 2011</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Preoxygenation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Apnea</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">PEEP</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Head-up tilt</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ramkumar</subfield>
   <subfield code="D">Venkateswaran</subfield>
   <subfield code="u">Department of Anaesthesiology, Kasturba Medical College, 576104, Manipal, Karnataka, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Umesh</subfield>
   <subfield code="D">Goneppanavar</subfield>
   <subfield code="u">Department of Anaesthesiology, Kasturba Medical College, 576104, Manipal, Karnataka, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Philip</subfield>
   <subfield code="D">Frenny</subfield>
   <subfield code="u">Department of Anaesthesiology, Kasturba Medical College, 576104, Manipal, Karnataka, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Anesthesia</subfield>
   <subfield code="d">Springer Japan</subfield>
   <subfield code="g">25/2(2011-04-01), 189-194</subfield>
   <subfield code="x">0913-8668</subfield>
   <subfield code="q">25:2&lt;189</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">25</subfield>
   <subfield code="o">540</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00540-011-1098-3</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00540-011-1098-3</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ramkumar</subfield>
   <subfield code="D">Venkateswaran</subfield>
   <subfield code="u">Department of Anaesthesiology, Kasturba Medical College, 576104, Manipal, Karnataka, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Umesh</subfield>
   <subfield code="D">Goneppanavar</subfield>
   <subfield code="u">Department of Anaesthesiology, Kasturba Medical College, 576104, Manipal, Karnataka, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Philip</subfield>
   <subfield code="D">Frenny</subfield>
   <subfield code="u">Department of Anaesthesiology, Kasturba Medical College, 576104, Manipal, Karnataka, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Anesthesia</subfield>
   <subfield code="d">Springer Japan</subfield>
   <subfield code="g">25/2(2011-04-01), 189-194</subfield>
   <subfield code="x">0913-8668</subfield>
   <subfield code="q">25:2&lt;189</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">25</subfield>
   <subfield code="o">540</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
