<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445374772</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317142959.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110401xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00540-010-1077-0</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00540-010-1077-0</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Transcutaneous pressure at which the internal jugular vein is collapsed on ultrasonic imaging predicts easiness of the venous puncture</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Woo Joo, Michihiko Fukui, Kunihiko Kooguchi, Masahiro Sakaguchi, Taiichi Shinzato]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Even though we use ultrasound guidance for central venous puncture, we sometimes experience difficulties. We infer that in such cases the vein is collapsed and that the transcutaneous ultrasound probe pressure at which the vein is collapsed (P tc) may predict the easiness of the venous puncture. We measured P tc and the diameter of the internal jugular vein in 47 adult patients in our ICU. After successful puncture, we also measured venous pressure (P v). The patients were divided into two groups based on the number of puncture attempts: ≥3 attempts constituted the &quot;difficult group” and &lt;3 attempts was considered the &quot;easy group:” 33 patients were in the easy group and 14 patients were in the difficult group. The easy group showed significantly higher P tc value (9.3±3.8 vs. 3.5±0.9cmH2O, P&lt;0.0001) and larger vertical diameter (9.2±3.1 vs. 6.8±2.2mm, P=0.013) than the difficult group. We observed a clear border between the minimum P tc in the easy group (6cmH2O) and the maximum value in the difficult group (5cmH2O). In conclusion, venous collapsibility and vertical diameter determine difficulty in performing venous puncture.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Japanese Society of Anesthesiologists, 2011</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Central venous catheterization</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Ultrasound</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Intensive care</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Venous pressure</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Joo</subfield>
   <subfield code="D">Woo</subfield>
   <subfield code="u">Department of Emergency and Intensive Care Medicine, Otsu Municipal Hospital, 2-9-9 Motomiya, 520-0804, Otsu, Shiga, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Fukui</subfield>
   <subfield code="D">Michihiko</subfield>
   <subfield code="u">Department of Emergency and Intensive Care Medicine, Otsu Municipal Hospital, 2-9-9 Motomiya, 520-0804, Otsu, Shiga, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kooguchi</subfield>
   <subfield code="D">Kunihiko</subfield>
   <subfield code="u">Department of Emergency and Intensive Care Medicine, Otsu Municipal Hospital, 2-9-9 Motomiya, 520-0804, Otsu, Shiga, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Sakaguchi</subfield>
   <subfield code="D">Masahiro</subfield>
   <subfield code="u">Department of Emergency and Intensive Care Medicine, Otsu Municipal Hospital, 2-9-9 Motomiya, 520-0804, Otsu, Shiga, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Shinzato</subfield>
   <subfield code="D">Taiichi</subfield>
   <subfield code="u">Department of Emergency and Intensive Care Medicine, Otsu Municipal Hospital, 2-9-9 Motomiya, 520-0804, Otsu, Shiga, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Anesthesia</subfield>
   <subfield code="d">Springer Japan</subfield>
   <subfield code="g">25/2(2011-04-01), 308-311</subfield>
   <subfield code="x">0913-8668</subfield>
   <subfield code="q">25:2&lt;308</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">25</subfield>
   <subfield code="o">540</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00540-010-1077-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">brief-communication</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00540-010-1077-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Joo</subfield>
   <subfield code="D">Woo</subfield>
   <subfield code="u">Department of Emergency and Intensive Care Medicine, Otsu Municipal Hospital, 2-9-9 Motomiya, 520-0804, Otsu, Shiga, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Fukui</subfield>
   <subfield code="D">Michihiko</subfield>
   <subfield code="u">Department of Emergency and Intensive Care Medicine, Otsu Municipal Hospital, 2-9-9 Motomiya, 520-0804, Otsu, Shiga, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kooguchi</subfield>
   <subfield code="D">Kunihiko</subfield>
   <subfield code="u">Department of Emergency and Intensive Care Medicine, Otsu Municipal Hospital, 2-9-9 Motomiya, 520-0804, Otsu, Shiga, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Sakaguchi</subfield>
   <subfield code="D">Masahiro</subfield>
   <subfield code="u">Department of Emergency and Intensive Care Medicine, Otsu Municipal Hospital, 2-9-9 Motomiya, 520-0804, Otsu, Shiga, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Shinzato</subfield>
   <subfield code="D">Taiichi</subfield>
   <subfield code="u">Department of Emergency and Intensive Care Medicine, Otsu Municipal Hospital, 2-9-9 Motomiya, 520-0804, Otsu, Shiga, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Anesthesia</subfield>
   <subfield code="d">Springer Japan</subfield>
   <subfield code="g">25/2(2011-04-01), 308-311</subfield>
   <subfield code="x">0913-8668</subfield>
   <subfield code="q">25:2&lt;308</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">25</subfield>
   <subfield code="o">540</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
