<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445802790</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317145146.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110501xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10337-011-1956-z</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10337-011-1956-z</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Reproducibility of Programmed-Temperature Retention Indices under Average Linear Velocity Carrier Gas Control of GC and GC-MS</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[H. Miyagawa, K. Nakagawa, K. Kadokami]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Programmed-temperature retention indices (PTRIs) are useful for the identification and quantification of chemicals by means of GC and GC/MS. To obtain reproducible PTRIs, we studied the influence of average linear velocity and column length under the constant average linear velocity control (CVC) using 55 pesticides and 33 fatty acid methyl esters. The PTRIs decreased with increasing average linear velocity, and the degree of decrease differs with the compounds. The PTRIs, however, were almost constant as long as the same average linear velocity was used even if the column length was changed. In addition, the correlation between the variation ratio in PTRI and the increase in average linear velocity was linear. Using the linear relationship between PTRIs and average linear velocities under CVC, highly reproducible PTRIs were obtained even if the capillary column length changes. Furthermore, the PTRIs determined by GC with FID, ECD, and FPD under atmospheric pressure were applied to GC/MS under vacuum or vice versa. From these results, it was confirmed that because CVC provides reproducible retention indices, CVC is advantageous for qualitative and quantitative analysis by GC and GC/MS.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2011</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">GC/MS</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Carrier gas flow control</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Column length</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Pesticides</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Fatty acid methyl esters</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Programmed-temperature retention indices</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Miyagawa</subfield>
   <subfield code="D">H.</subfield>
   <subfield code="u">SHIMADZU Corporation, 1, Nishinokyo-Kuwabaracho Nakagyo-ku, 604-8511, Kyoto, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Nakagawa</subfield>
   <subfield code="D">K.</subfield>
   <subfield code="u">SHIMADZU Corporation, 1, Nishinokyo-Kuwabaracho Nakagyo-ku, 604-8511, Kyoto, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kadokami</subfield>
   <subfield code="D">K.</subfield>
   <subfield code="u">Faculty of Environmental Engineering, The University of Kitakyushu, Hibikino, Wakamatsu-ku, 808-0135, Kitakyushu, Fukuoka, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Chromatographia</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">73/9-10(2011-05-01), 953-963</subfield>
   <subfield code="x">0009-5893</subfield>
   <subfield code="q">73:9-10&lt;953</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">73</subfield>
   <subfield code="o">10337</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10337-011-1956-z</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10337-011-1956-z</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Miyagawa</subfield>
   <subfield code="D">H.</subfield>
   <subfield code="u">SHIMADZU Corporation, 1, Nishinokyo-Kuwabaracho Nakagyo-ku, 604-8511, Kyoto, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Nakagawa</subfield>
   <subfield code="D">K.</subfield>
   <subfield code="u">SHIMADZU Corporation, 1, Nishinokyo-Kuwabaracho Nakagyo-ku, 604-8511, Kyoto, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kadokami</subfield>
   <subfield code="D">K.</subfield>
   <subfield code="u">Faculty of Environmental Engineering, The University of Kitakyushu, Hibikino, Wakamatsu-ku, 808-0135, Kitakyushu, Fukuoka, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Chromatographia</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">73/9-10(2011-05-01), 953-963</subfield>
   <subfield code="x">0009-5893</subfield>
   <subfield code="q">73:9-10&lt;953</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">73</subfield>
   <subfield code="o">10337</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
