<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445812710</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317145216.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110301xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00411-010-0330-0</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00411-010-0330-0</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Dose estimation for astronauts using dose conversion coefficients calculated with the PHITS code and the ICRP/ICRU adult reference computational phantoms</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Tatsuhiko Sato, Akira Endo, Lembit Sihver, Koji Niita]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Absorbed-dose and dose-equivalent rates for astronauts were estimated by multiplying fluence-to-dose conversion coefficients in the units of Gy.cm2 and Sv.cm2, respectively, and cosmic-ray fluxes around spacecrafts in the unit of cm−2s−1. The dose conversion coefficients employed in the calculation were evaluated using the general-purpose particle and heavy ion transport code system PHITS coupled to the male and female adult reference computational phantoms, which were released as a common ICRP/ICRU publication. The cosmic-ray fluxes inside and near to spacecrafts were also calculated by PHITS, using simplified geometries. The accuracy of the obtained absorbed-dose and dose-equivalent rates was verified by various experimental data measured both inside and outside spacecrafts. The calculations quantitatively show that the effective doses for astronauts are significantly greater than their corresponding effective dose equivalents, because of the numerical incompatibility between the radiation quality factors and the radiation weighting factors. These results demonstrate the usefulness of dose conversion coefficients in space dosimetry.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2010</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Sato</subfield>
   <subfield code="D">Tatsuhiko</subfield>
   <subfield code="u">Japan Atomic Energy Agency, 2-4, Shirakata-Shirane, Tokai, 319-1195, Ibaraki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Endo</subfield>
   <subfield code="D">Akira</subfield>
   <subfield code="u">Japan Atomic Energy Agency, 2-4, Shirakata-Shirane, Tokai, 319-1195, Ibaraki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Sihver</subfield>
   <subfield code="D">Lembit</subfield>
   <subfield code="u">Chalmers University of Technology, 41296, Gothenburg, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Niita</subfield>
   <subfield code="D">Koji</subfield>
   <subfield code="u">Research Organization for Information Science and Technology, 2-4, Shirakata-Shirane, Tokai, 319-1106, Ibaraki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Radiation and Environmental Biophysics</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">50/1(2011-03-01), 115-123</subfield>
   <subfield code="x">0301-634X</subfield>
   <subfield code="q">50:1&lt;115</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">50</subfield>
   <subfield code="o">411</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00411-010-0330-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00411-010-0330-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Sato</subfield>
   <subfield code="D">Tatsuhiko</subfield>
   <subfield code="u">Japan Atomic Energy Agency, 2-4, Shirakata-Shirane, Tokai, 319-1195, Ibaraki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Endo</subfield>
   <subfield code="D">Akira</subfield>
   <subfield code="u">Japan Atomic Energy Agency, 2-4, Shirakata-Shirane, Tokai, 319-1195, Ibaraki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Sihver</subfield>
   <subfield code="D">Lembit</subfield>
   <subfield code="u">Chalmers University of Technology, 41296, Gothenburg, Sweden</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Niita</subfield>
   <subfield code="D">Koji</subfield>
   <subfield code="u">Research Organization for Information Science and Technology, 2-4, Shirakata-Shirane, Tokai, 319-1106, Ibaraki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Radiation and Environmental Biophysics</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">50/1(2011-03-01), 115-123</subfield>
   <subfield code="x">0301-634X</subfield>
   <subfield code="q">50:1&lt;115</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">50</subfield>
   <subfield code="o">411</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
