<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">445812966</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180317145217.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170323e20110801xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00411-011-0365-x</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00411-011-0365-x</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Scanning irradiation device for mice in vivo with pulsed and continuous proton beams</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Christoph Greubel, Walter Assmann, Christian Burgdorf, Günther Dollinger, Guanghua Du, Volker Hable, Alexander Hapfelmeier, Ralf Hertenberger, Peter Kneschaurek, Dörte Michalski, Michael Molls, Sabine Reinhardt, Barbara Röper, Stefan Schell, Thomas Schmid, Christian Siebenwirth, Tatiana Wenzl, Olga Zlobinskaya, Jan Wilkens]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A technical set-up for irradiation of subcutaneous tumours in mice with nanosecond-pulsed proton beams or continuous proton beams is described and was successfully used in a first experiment to explore future potential of laser-driven particle beams, which are pulsed due to the acceleration process, for radiation therapy. The chosen concept uses a microbeam approach. By focusing the beam to approximately 100×100μm2, the necessary fluence of 109 protons per cm2 to deliver a dose of 20Gy with one-nanosecond shot in the Bragg peak of 23MeV protons is achieved. Electrical and mechanical beam scanning combines rapid dose delivery with large scan ranges. Aluminium sheets one millimetre in front of the target are used as beam energy degrader, necessary for adjusting the depth-dose profile. The required procedures for treatment planning and dose verification are presented. In a first experiment, 24 tumours in mice were successfully irradiated with 23MeV protons and a single dose of 20Gy in pulsed or continuous mode with dose differences between both modes of 10%. So far, no significant difference in tumour growth delay was observed.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag, 2011</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Greubel</subfield>
   <subfield code="D">Christoph</subfield>
   <subfield code="u">Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, 85579, Neubiberg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Assmann</subfield>
   <subfield code="D">Walter</subfield>
   <subfield code="u">Fakultät für Physik, Ludwig-Maximilians-Universität München, 85748, Garching, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Burgdorf</subfield>
   <subfield code="D">Christian</subfield>
   <subfield code="u">Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, 85579, Neubiberg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Dollinger</subfield>
   <subfield code="D">Günther</subfield>
   <subfield code="u">Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, 85579, Neubiberg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Du</subfield>
   <subfield code="D">Guanghua</subfield>
   <subfield code="u">Physik Department E12, Technische Universität München, 85748, Garching, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hable</subfield>
   <subfield code="D">Volker</subfield>
   <subfield code="u">Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, 85579, Neubiberg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hapfelmeier</subfield>
   <subfield code="D">Alexander</subfield>
   <subfield code="u">Institut für Medizinische Statistik und Epidemiologie, Technische Universität München, Klinikum rechts der Isar, 81675, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hertenberger</subfield>
   <subfield code="D">Ralf</subfield>
   <subfield code="u">Fakultät für Physik, Ludwig-Maximilians-Universität München, 85748, Garching, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kneschaurek</subfield>
   <subfield code="D">Peter</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Michalski</subfield>
   <subfield code="D">Dörte</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Molls</subfield>
   <subfield code="D">Michael</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Reinhardt</subfield>
   <subfield code="D">Sabine</subfield>
   <subfield code="u">Fakultät für Physik, Ludwig-Maximilians-Universität München, 85748, Garching, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Röper</subfield>
   <subfield code="D">Barbara</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Schell</subfield>
   <subfield code="D">Stefan</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Schmid</subfield>
   <subfield code="D">Thomas</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Siebenwirth</subfield>
   <subfield code="D">Christian</subfield>
   <subfield code="u">Physik Department E12, Technische Universität München, 85748, Garching, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Wenzl</subfield>
   <subfield code="D">Tatiana</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Zlobinskaya</subfield>
   <subfield code="D">Olga</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Wilkens</subfield>
   <subfield code="D">Jan</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Radiation and Environmental Biophysics</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">50/3(2011-08-01), 339-344</subfield>
   <subfield code="x">0301-634X</subfield>
   <subfield code="q">50:3&lt;339</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">50</subfield>
   <subfield code="o">411</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00411-011-0365-x</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00411-011-0365-x</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Greubel</subfield>
   <subfield code="D">Christoph</subfield>
   <subfield code="u">Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, 85579, Neubiberg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Assmann</subfield>
   <subfield code="D">Walter</subfield>
   <subfield code="u">Fakultät für Physik, Ludwig-Maximilians-Universität München, 85748, Garching, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Burgdorf</subfield>
   <subfield code="D">Christian</subfield>
   <subfield code="u">Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, 85579, Neubiberg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Dollinger</subfield>
   <subfield code="D">Günther</subfield>
   <subfield code="u">Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, 85579, Neubiberg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Du</subfield>
   <subfield code="D">Guanghua</subfield>
   <subfield code="u">Physik Department E12, Technische Universität München, 85748, Garching, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hable</subfield>
   <subfield code="D">Volker</subfield>
   <subfield code="u">Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, 85579, Neubiberg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hapfelmeier</subfield>
   <subfield code="D">Alexander</subfield>
   <subfield code="u">Institut für Medizinische Statistik und Epidemiologie, Technische Universität München, Klinikum rechts der Isar, 81675, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hertenberger</subfield>
   <subfield code="D">Ralf</subfield>
   <subfield code="u">Fakultät für Physik, Ludwig-Maximilians-Universität München, 85748, Garching, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kneschaurek</subfield>
   <subfield code="D">Peter</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Michalski</subfield>
   <subfield code="D">Dörte</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Molls</subfield>
   <subfield code="D">Michael</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Reinhardt</subfield>
   <subfield code="D">Sabine</subfield>
   <subfield code="u">Fakultät für Physik, Ludwig-Maximilians-Universität München, 85748, Garching, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Röper</subfield>
   <subfield code="D">Barbara</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Schell</subfield>
   <subfield code="D">Stefan</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Schmid</subfield>
   <subfield code="D">Thomas</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Siebenwirth</subfield>
   <subfield code="D">Christian</subfield>
   <subfield code="u">Physik Department E12, Technische Universität München, 85748, Garching, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Wenzl</subfield>
   <subfield code="D">Tatiana</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Zlobinskaya</subfield>
   <subfield code="D">Olga</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Wilkens</subfield>
   <subfield code="D">Jan</subfield>
   <subfield code="u">Klinik für Strahlentherapie und Radiologische Onkologie, Technische Universität München, Klinikum rechts der Isar, München, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Radiation and Environmental Biophysics</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">50/3(2011-08-01), 339-344</subfield>
   <subfield code="x">0301-634X</subfield>
   <subfield code="q">50:3&lt;339</subfield>
   <subfield code="1">2011</subfield>
   <subfield code="2">50</subfield>
   <subfield code="o">411</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
